Boltek ERL-10 User Manual

Erl-10 lightning relay module, Short range system, Lightning detection systems

Advertising
background image

Lightning Detection Systems

Short Range System

ERL-10 Lightning Relay Module

Stacklight connected

to an ERL-10

(stacklight not

included)

ERL-10 Status

Monitor Soft ware

(included)

[email protected] www.boltek.com Tel. +1 (905) 734-8045

Confi gurable for 1, 2 or 3 alarms levels (Red,

Red/Yellow, Red/Orange/Yellow)

All Clear output (Green)

Confi gurable alarm distances and durations

20 miles / 37 km range, optionally extendable to

50+ miles/80km

Coincidence Mode virtually eliminates false

alarms

Fault output indicates status of the system

Status Monitor soft ware shows current alarm

state and minutes : seconds until All Clear

USB port for confi guration and/or Status Moni-

tor soft ware

RS-485 output for transmitting status messages

to other equipment and/or to a distant Status
Monitor computer

Operation
Th

e ERL-10 receives data from the EFM-100 Electric Field

Mill short-range sensor (<20 miles/32 km) and optionally
also an LD-250 long range lightning detector. It constantly
monitors for lightning and activates its timed relay outputs
when lightning is detected. Up to three alarms can be con-
fi gured, referred to as Red, Orange and Yellow Alert levels.
Th

e green All Clear state is entered when no lightning has

been detected within the confi gured time period.

When the ERL-10 is fi rst turned on it enters Survey Mode
where it looks for lightning. Aft er several minutes without
lightning (confi gurable but typically 10-20 minutes) the
system enters the All Clear state. Th

e green All Clear light

on the ERL-10 illuminates and the All Clear relay output
activates.

Coincidence Mode
With Coincidence Mode enabled a lightning strike must be
detected by both the EFM-100 and LD-250 for an alarm to
activate. Th

is virtually eliminates false alarms that could be

caused by persons, animals, insects, etc. near the EFM-100
sensor. Coincidence Mode is only applicable within the
range of the EFM-100 (0-20 miles/0-32 km)

Status Monitor
Th

e ERL-10 Status Monitor soft ware (included) allows

the system status and countdown timers to be displayed.
Countdown timers clearly indicate the number of minutes
until All Clear. Alarm activations are timestamped and
logged to disk. Graphical log fi le viewing soft ware is also
included.

ERL-10-SS-09202012 page 1/2

©2012 Boltek Corp. All rights reserved

All Clear

status

Advertising