Feature

ICX 6430

ICX 6450

FCX

ICX 6610

ICX 6650

FSX 800
FSX 1600

ICX 7750

Traffic counters for outbound traffic

08.0.01

08.0.01

No

No

No

08.0.01

08.0.10

Egress queue counters

No

No

08.0.01

08.0.01

08.0.01

No

No

Remote monitoring (RMON)

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Specifying the maximum number of
entries allowed in the RMON Control
Table

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

sFlow version 2

No

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

sFlow version 5 (default)

No

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

sFlow support for IPv6 packets

No

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Uplink utilization lists

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Operations, administration, and maintenance (OAM)

Documents software features supporting OAM.

The following features are documented in the FastIron Ethernet Switch Administration Guide.

Feature

ICX 6430

ICX 6450

FCX

ICX 6610

ICX 6650

FSX 800
FSX 1600

ICX 7750

Flash and boot code verification

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Flash image verification

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Software upgrade via CLI

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Software upgrade via SNMP

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Hitless failover

08.0.01
Only when
stacked

008.0.01
Only when
stacked

08.0.01
Only when
stacked

08.0.01
Only when
stacked

N/A

08.0.01

N/A

Hitless switchover

08.0.01
Only when
stacked

08.0.01
Only when
stacked

08.0.01
Only when
stacked

08.0.01
Only when
stacked

N/A

08.0.01

N/A

Hitless OS upgrade

No

No

No

No

No

08.0.01

No

Boot code synchronization for active and
redundant management modules

N/A

N/A

N/A

N/A

No

08.0.01

No

Software reboot

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Show boot preference

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Loading and saving configuration files

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

System reload scheduling

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.01

08.0.10

Operations, administration, and maintenance (OAM)