Brocade Network Advisor Installation and Migration Guide (Supporting Network Advisor 12.3.0) User Manual

Page 51

Advertising
background image

Brocade Network Advisor Installation and Migration Guide

31

53-1003157-01

Smart Card driver installation

2

5. Create a soft link into the system directory. This is to support the automatic restart of the pcscd

daemon upon system restart.

If you installed the pcsc directory into the /opt directory, just create the soft link. Otherwise,
use the name of the new directory in place of /opt.

S.u.s.e> ln –s /opt/pcsc/pcscctl /etc/init.d/pcscd

S.u.s.e> chkconfig --add pcscd

or

redhat> ln –s /opt/pcsc/pcscctl /etc/init.d/pcscd

redhat> chkconfig --add pcscd

NOTE

Before you enter chkconfig --add pcscd, you can enter chkconfig –list |
grep pcscd

to verify that the pcscd file is already on the list. If it already exists, you do

not need to enter chkconfig –add pcscd. After you reboot the system, you should
expect the following links under /etc/rc2.d, /etc/rc3.d, /etc/rc3.d, /etc/rc4.d, and
/etc/rc5.d.

lrwxrwxrwx 1 root root 15 Jul 28 01:50 S94pcscd -> ../init.d/pcscd

NOTE

For some Linux vendors, the Smart Card driver may come with the operating system. In
this case, extra system configuration may be needed. For more information, refer to

“Detecting and correcting a default Linux Smart Card driver”

on page 32.

6. Start the pcscd daemon or stop the pcscd daemon.

To start pcscd, type:

> /opt/pcsc/pcscctl start

To stop pcscd, type:

> /opt/pcsc/pcscctl stop

Advertising