Viewing existing cimom servers – Brocade Network Advisor Port Commissioning Quick Start Guide (Supporting Network Advisor 12.3.0) User Manual

Page 7

Advertising
background image

Brocade Network Advisor Port Commissioning Quick Start Guide

7 of 21

Publication Number: 53-1003220-01

Viewing existing CIMOM servers

NOTE

Port commissioning is only supported on FICON devices running Fabric OS 7.1 or later.

Before you can decommission or recommission an F-Port, you must register the CIMOM servers within the fabric
affected by the action. For more information, refer to

“Registering a CIMOM server”

on page 5.

1. Select Configure > Port Commissioning > Setup.

The Port Commissioning Setup dialog box displays (

Figure 1

).

The Port Commissioning Setup dialog box has two main areas. The Add/Edit Systems and Credentials area
enables you to register CIMOM servers (system and credentials) one at a time and contains the following fields
and components:

Network Address — Enter the IP address (IPv4 or Ipv6 format) or host name of the CIMOM server in the field.

Description — (Optional) Enter a description of the CIMOM server in the field. The description cannot be over
1024 characters.

CIMOM Port — Enter the CIMOM port number for the CIMOM server in the field. The default port number is
5989.

Namespace — Enter the namespace of the CIM_FCPort in the field. The default namespace is root/cimv2.

Credentials - User ID (Optional) — Enter a user identifier for the CIMOM server in the field. The credentials
user identifier cannot be over 128 characters.

Credentials - Password (Optional) — Enter a password in the field. The password cannot be over 512
characters.

Left arrow button — Select a CIMOM server in the Systems List and click to move the defined CIMOM server
credentials to the Add/Edit Systems and Credentials area for editing or deletion.

Right arrow button — Click to move the defined CIMOM server credentials form the Add/Edit Systems and
Credentials area to the Systems List.

The Systems List details the defined CIMOM server and contains the following data:

Network Address — The IP address (IPv4 or Ipv6 format) or host name of the system.

Description — User-defined description of the system.

CIMOM Port — The CIMOM port number of the system.

Namespace — The namespace of the CIM_FCPort.

User ID — The user identifier for the system.

Status — The system connectivity status. Updates when you test the reachability of the CIMOM server and
when you contact the CIMOM server to respond to the F-Port decommission or recommission request. Valid
status options include:

OK — CIMOM server contact successful with current credentials.

Not Contacted Yet — CIMOM servers configured, connectivity not tested yet.

Credentials Updated — Credentials changed, connectivity not tested yet.

Credentials Failed — CIMOM server contact failed with current credentials.

Not Reachable — CIMOM server not reachable.

Wrong Namespace — CIMOM server namespace is incorrect.

Last Contacted — The last time you contacted the system. Updates when you test the reachability of the
CIMOM server and when you contact the CIMOM server to respond to the F-Port decommission or
recommission request.

Advertising