SAFETY INSTRUCTIONS:

This fine pump that you have just purchased is designed from the latest in material and
workmanship. Before installation and operation, we recommend the following procedures:

Check with your local electrical and plumbing codes to ensure you comply with the
regulations. These codes have been designed with your safety in mind. Be sure you
comply with them.

We recommend that a separate circuit be lead from the home electrical distribution
panel properly protected with a fuse or a circuit breaker. We also recommend that a
ground fault circuit be used. Consult a licensed electrician for all wiring.

The ground terminal on the three prong plugs should never be removed. They are
supplied and designed for your protection.

Never make adjustements to any electrical appliance or product with the power
connected. Do not only unscrew the fuse or trip the breaker, remove the power plug
from the receptacle.

A

B

C

D

Material required for submersible sump pump application

Submersible sump pump installation



Desired length of 1 1/2” or 1 1/4” of ABS/DWV pipe to link up the pump to the drain line.



1 only 1 1/4” check valve (350353) (Note that this 1 1/4” check valve may also be use with

a 1 1/2” pipe).



Sump pit or 1 only sump basin.



1 1/4”-1 1/2” stainless steel clamps (750886).



ABS cement.

2

Tools

Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe
ends, pipe wrench, adjustable wrench to tighten fittings.

NOTICE

This unit is not designed for applications
to pump salt water or brine .
Use with salt water or brine will void

warranty.

ELECTRICAL CONNECTION

For pumping systems using more than one pump, each pump needs to be connected to a sepa-
rate dedicated circuit protected by a fuse or breaker. This way, the power supply of one pump will
not stop operating if the fuse of one of the pumps burns or if the breaker of one of the pumps trips.