Trouble shooting guide checklist, Trouble probable cause action – Burcam 300500 SUBMERSIBLE SUMP PUMP 1/3HP 115V User Manual

Page 6

Advertising
background image

6

TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.

Switch is off position
Blown fuse
Tripped breaker
Plug disconnected
Corroded plug
Low water level
Thermal overcharge
Defective switch/float
Defective motor
Improper float position

Jammed impeller
Plugged check valve
Blocked suction/inlet
Discharge leak
Blocked line/pipe
Worn impeller
Defective motor

Defective switch
Float obstruction
Blocked suction/inlet

Turn switch to on position
Replace
Reset
Re-install
Clean prongs
Add water and verify
Cool the motor
Replace
Replace/repair
Check movement

Clean
Clean/replace
Check for debris in pit and clean
Repair
Check for debris or ice
Repair/replace
Replace

Replace
Adjust/check
Check for debris in pit and clean

TROUBLE PROBABLE CAUSE ACTION

Motor does not
run.

Pump does not
shut off.

Pump does not
deliver to full
capacity.

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.

Advertising