3.2.6

Input Port (PN 59761) - Removal and Installation

Tools required:

Phillips screwdriver
7/16" open end wrench
9/16" open end wrench
5/8" open end wrench

Removal:

1. Remove cover from its enclosure as described in Section 3.2.2 on page 4, and place on a bench top.

2. From inside of back panel, disconnect the tubing section that connects to the male tube connector (PN

57705) fitting.

3. Remove the AN bulkhead end nut and ferrules, note orientation, from AN bulkhead fitting.

4. Remove from bulkhead, but leave assembled, tube adapter (PN 56223) and male tube connector (PN

57705) fittings. Remove filter (PN 54188) from inside tube adapter fitting.

5. Using a wrench on the AN bulkhead lock nut from inside of back panel, turn the lock nut

counter-clockwise. Slide input port AN bulkhead fitting out from outside of back panel.

Installation:

1. Before installing a new input port AN bulkhead fitting, remove the end nut and ferrules (note orientation)

from AN bulkhead fitting.

2. Slide input port AN bulkhead fitting in from outside of back panel. Adjust the AN bulkhead fitting to

line-up with the fastener.

3. Thread AN bulkhead lock nut and turn clockwise finger tight.

4. If required, install hex plate fastener (PN 59712) over AN bulkhead input port fitting and onto rear panel,

with screw (PN 14845). Adjust the AN bulkhead fitting to line-up the screw hole with the fastener.

5. Using a 5/8" wrench on the AN bulkhead lock nut from inside of back panel, turn the lock nut clockwise

to tighten.

6. Install filter (PN 54188) inside tube adapter fitting (PN 56223).

7. From inside of back panel, install the AN bulkhead end nut and ferrules (in proper orientation) on AN

bulkhead fitting. Thread end nut loosely.

8. Slide assembled, tube adapter (PN 56223) and male tube connector (PN 57705) fittings (with filter) into

AN bulkhead fitting.

9. Tighten the AN bulkhead end nut approximately 1-1 /4 turns beyond finger tight, using 9/16" wrench.

10. Attach the tubing section that connects to the male tube connector (PN 57705) fitting.

11. Test UVC1000/UVC1010 as described in Section 3.2.1 on page 4.

3.2.7

Input Port Filter (PN 54188) - Removal, Cleaning and Installation

The port filter is a sintered element filter that can be easily removed for inspection and cleaning.

Tools required:

7/16" open end wrench
9/16" open end wrench
A/R solvent (de-natured alcohol)

Removal and Cleaning:

1. Remove cover from its enclosure as described in Section 3.2.2 on page 4, and place on a bench top.

2. From inside of rear panel, remove the AN bulkhead tubing end nut and ferrules (note orientation) from

input port AN bulkhead fitting. Remove filter (PN 54188) from inside tube adapter fitting (PN 56223).

NOTE:

Leave fittings attached to tubing.

3. Clean the filter in solvent (de-natured alcohol) and blow-dry with compressed air.

Installation:

1. Slide filter into fractional tube adapter fitting (PN 56223), attached to nylon tubing.

2. Slide tubing end nut and ferrules in proper order over AN bulkhead fitting. Thread end nut loosely.