WALL TILING

If the cooker is to stand in a recess or against a wall which is to be tiled in no circumstances should the tiles overlap the range top
plate.

GAS SUPPLY - U.S. PIPE THREADS

NOTE: A GAS CONTROL VALVE MUST BE INSTALLED IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT
SUPPLIED).

9.5mm (3/8in) N.P.T. Male connection near the front of the range on the LH or RH side. (Optional).

ALL GAS CONTROLS MUST BE U.S. PIPE THREADS.

Maximum Heat Input: 4.4kW (15,000 Btu/h).

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressure in excess of 1/2 psig (3.5kPa). The appliance must be isolated from the gas supply piping
system by closing the individual manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5kPa).

APPLIANCE DIMENSIONS