Use of equipment, Installation, Operation – Hired-Hand RollSeal Rollup Curtains: Ridder Motor Control User Manual

Page 4: Wiring diagrams, schematics, etc, 1 tools required, 2 instructions, 1 power supply to ridder controller

Advertising
background image

4801-5081

Ridder Motor Control

2

4. Use of Equipment

This Controller is designed to use as a driver for Ridder motors. It is set up to only be used with

the motors listed in the rating and specification part above. These motors are used in ways such as Rollseal
curtains and green house roof system.

5. Installation

5.1 Tools Required

Electric Drill, Phillips Screwdriver, Standard Screwdriver, Mini Screwdriver, WireStrippers

5.2 Instructions

1. Hang controller using four screws.
2. Drill holes in box for using elliots or conduit.

Warning: All holes must be to the right half of controller in bottom of controller.

3. Connect Power Supply to controller using diagram 7.1.
4. Connect motor and limit switches using diagram 7.2.
5. Connect automatic control source using diagrams 7.3 - 7.6.
6. Set limits on motor.

6. Operation

When controller is in manual position motor will operate off of Open /Close switch. When flipped

to Auto the controller works off of external control source such as a thermostat or electronic controller.

7. Wiring Diagrams, Schematics, etc.

7.1 Power Supply to Ridder Controller

1

GND

9

12

10

8

7

6

5

4

3

2

11 12 13 14 15 16 17 18

L1

L2

HO

T

OP

E

N

CLO

SE

GND

U1

W2

V1

U2

W1

1

3

7

9

4

CONTROL MOTOR RIDDER RW245

OUT

P O W E R

240V

SWITCH

CLOSED

SWITCH SWITCH

OPEN

SAFETY

V1

W2

3

1

9

7

TO REVERSE

1

GND

9

12

10

8

7

6

5

4

3

2

11 12 13 14 15 16 17 18

L1

L2

HOT

OP

E

N

CLO

SE

GND

U1

W2

V1

U2

W1

1

3

7

9

4

CONTROL MOTOR RIDDER RW245

OUT

P O W E R

240V

SWITCH

CLOSED

SWITCH SWITCH

OPEN

SAFETY

V1

W2

3

1

9

7

TO REVERSE

Ridder Control

Ridder Control

Connecting multiple Ridder Controls to

one control source.

Warning: All controllers must have the

same power supply connected in parallel

to L1 and L2.

240V

Power

Supply

Advertising