Installation – Hired-Hand Mega Flow SlantWall Fans: Insulation Panel - Installation User Manual

Page 2

Advertising
background image

HIRED-HAND, INC. • 1733 County Road 68 • Bremen, Alabama 35033 · Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4801-5344 rev 6-07

Page 2 of 4

INSTALLATION


























































STEP 1

Remove shutters and any other obstructions
from the back of the 52” MegaFlow Slant Wall Fan
so the MegaFlow Insulation Panel is able to cover
the back-hole of the fan completely.

STEP 4

Place the MegaFlow Insulation Panel (6509-
7200) on the back frame of the fan. Rotate the
clamps so they hold the panel in place and then
tighten each clamp with the wing nut to complete
installation. See Figures 3 and 4.

Insert each clamp into the U-shaped hole,
pinching the fan between the panel holder of the
clamp. Loosely tighten each clamp with the wing
nut (1001-5012) and align the metal strips with the
direction of the fan. See Figure 2.

STEP 3

STEP 2

Assemble the clamp by placing the bent strip of
metal (0404-10345) through the screw of the other
piece (6409-8000). The bend should go away from
the piece with the screw as shown in Figure 1.
Loosen the clamp enough to fit in the U-shaped
slits on the fan.

Figure 1 – Assembling
the clamp.

Insert as shown,
and then loosely
tighten

Rotate
clamp,
then
tighten
wing nut
completely

Figure 3 –
Installing the
Insulation Panel

Figure 2 –
Inserting the
clamps

Figure 4 –
Clamping down
the fan

Advertising