Hired-Hand Mega Flow SlantWall Fans: METAL CONE Installation Rev 9-05 User Manual

Mega-flow metal cone, Warning, Installation

Advertising
background image

HIRED-HAND MFG., INC.

• 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4801-5128 Rev 9-05 Page

1

of

4

Outs

ide E

dge

Insid

e Ed

ge

Arrange panels for assembly
with flat sides down, flange
sides up. The bent tabs of
one panel should contact the
flange of adjacent panel.

Tab before
bending

Bend tab upward

Flange

Tabs

Figure 1

Joints

Mounting

Hole For

Wire guard





Packing List For One (1) Unit

Tools Required

Four (4) Cone Sections

Four (4) Corner Brackets

One (1) Wire Guard

Five (5) 3/8"-16 x 1 Cap Screws

7/16 in. (11 mm) Wrench

Ratchet

Sixteen (16) 1/4"-20 Nuts

Ten (10) 3/8" Washers

Sixteen (16) ¼"-20 x 3/4" Bolts

Five (5) 3/8"-16 Nuts

7/16 in. (11 mm) Socket

Sixteen (16) #14 x 1" TEK Screws

Cordless drill and bit

One (1) Installation Manual

(For Installing TEK screws)

Marker or Scribe

WARNING!

During Cone Installation Be Sure That Fan Motor Is Not Plugged Into Any Power Source.

Always Double Check Power Sources.


1. Refer to Figure 1. Lay cone pieces flat with their

flanges pointed up.

2. For each panel, bend tabs upward in same direction as

flange. NOTE: Bend tabs by hand. See Inset
Figure 1.



3. Arrange panels with flanges and tabs contacting as

shown in Figure 1. Align holes of flanges and tabs.

Instructions Continued On Next Page

D


































!

Assembly & Installation Of Cone

MEGA-FLOW METAL CONE

Installation

Advertising