Hired-Hand Super-Savers (Forced Air Heaters) XL: Igniter Replacement User Manual

Igniter replacement, Directions, Warning

Advertising
background image

Hired-Hand Mfg., Inc. • 1733 County Road 68 • Bremen, Alabama 35033 • Phone 256-287-1000 • Fax 256-287-2000

Sheet Part No. 4801-0142 Rev 2-07








CAUTION! Be sure that heater is cool before touching internal surfaces. These surfaces remain

hot enough to cause severe burns during and after operation.

Tools Required

11/32" Nut Driver

Materials

NOTICE: Igniter in kit depends upon operating voltage of heater unit (either 120 or 240 VAC)
























Directions

1. Disconnect power to the heater.
2. Disconnect the two lead wires from the existing igniter. Remove the 8-32 kep lock nut. Remove the

igniter

from the existing bracket. You will then be ready to install the new replacement bracket by

referencing one of the above figures.

3. If you have a 120,000 btu unit heater or larger then you will need to reference Figure-1 before installing

the replacement bracket. Remove the 8-32 kep lock nut and the flame probe from the existing bracket.
Once the flame probe is removed you are then ready to attach the replacement bracket and replace the
flame probe to the existing bracket. Secure them in place using two 8-32 kep lock nuts.

4. If you have a 75,000 btu unit heater or smaller then you will need to reference Figure-2. Attach the

replacement bracket and secure it in place using 8-32 kep lock nut.

5. After attaching the replacement bracket to the existing bracket insert the new igniter as shown in Figure-

3. Use 8-32 x ½

″ machine screw and nut to secure the igniter to the bracket.

6. Be sure the tip of the igniter extends over the top of the cast iron burner. Also be sure that the igniter

does not contact cast iron burner or heater internals.

7. Reconnect the wire leads from the harness to the new igniter leads.
8. Connect power to the heater, and check for proper operation.
9. Installation completed.

Voltage Part

No.

Quan.

Description

Voltage 120 VAC

3002-5000

1

IGNTR 120 vac Mini 2.5” Hot

Voltage 240 VAC

3002-5001

1

IGNTR 240 vac Mini 2.5” Hot

1001-2597 3 8-32

kep

nut

1004-0118 3 8-32 x ½

″ machine screw

0408-4390

1

FAB AS Brkt kit 2.5” Igniter

Igniter Replacement

Warning!

Disconnect All Electrical Power Sources To Heater Before Installing Igniter

Super Saver

®

XL Heaters

Advertising