Hired-Hand Super-Savers (Forced Air Heaters) XL: Direct Wire Flame Probe Kit User Manual

Direct wire flame probe kit, Warning, For super-saver xl heater

Advertising
background image

Direct Wire Flame Probe Kit

For Super-Saver XL Heater

HIRED-HAND MFG., INC.

1733 County Road 68 • Bremen, Alabama 35033 USA• Phone 256-287-1000 • Fax 256-287-2000

Manual Part No. 4802-5082 rev 3-06 Page

1 of 2

WARNING

Disconnect All Electrical Power Sources And Turn Off
Gas To Super-Saver Heater Before Conducting
Modifications!

WARNING

DO NOT perform modifications while unit is HOT!

Allow unit to cool!

15 mm Open-End Wrench

Wire Cutter

Needle-Nose Pliers

(Med-Lrg)

Philips

Screw-Driver

Wire Pliers

Flat-Head Screw-Driver

INSTRUCTIONS:

1. Disconnect electrical power and turn off the gas to the

Super-Saver Heater.

2. Disconnect the quick-connect receptacle to the

internal enclosure. Refer to Figure 1.

FIGURE 1

FIGURE 2


3. Loosen the receptacles two philips-head screws and

slide the braided wire sleeve away from the
receptacle. Refer to Figure 2.

4. Cut the yellow wire approximately 2” below the

receptacle, reassemble the sleeve and receptacle,
and reconnect to the enclosure. Refer to Figure 3.

FIGURE 3

FIGURE 4


5. Pull the yellow wire out of the opposite end of the wire

sleeve where the cord-set exits the heater.

6. Use a flat-head screwdriver to remove the internal

enclosures knock-out on the left side. Refer to
Figure 4.

7. Use needle-nose pliers to remove the CENTER

Yellow wire (FSI connection) from the electronic
module terminal block. Remove by pulling
STRAIGHT OUTWARD. Refer to Figure 5.

FIGURE 5

FIGURE 6


8. Cut this same Yellow wire approximately 1” from the

quick-connect male connector and discard this wire.
DO NOT CUT OTHER WIRES! Refer to Figure 6.

9. Reference the included parts list for a complete list of

components and descriptions. Refer to Figure 7 and
Table A.

FIGURE 7

TABLE A

6650-0400 Modification Kit Parts List

Part #

Description

Qty.

1901-6490 Replacement

Wire

Assy.

1

3006-0137

IDC (Insulation Disp. Conn.)

1

1013-5003 Nylon

Fitting,

Liquid-Tight

1

1044-2477 Tubing

2”

1003-5014 Flat

Washer,

7/16

2

1007-2299 Cable

Tie

2

1001-0108 Nylon

Nut,

Liquid-Tight

1

!

!

Quick Connect

Receptacle

Wire Sleeve

Knock-Out

Washers

IDC

Nylon Nut

Hose

Cable Ties

Wire Assy.

Nylon Fitting

Advertising