Connecting overload to a contactor, Connecting contactor to controller and loads, 1 evolution stage connections – Hired-Hand Contactor Control System (CCS): Triple Pole 16-Stage User Manual

Page 5: Manual operate switch

Advertising
background image

Part No. 4801-5321

Triple Pole 16-Stage Contactor Panel

3

8. Connecting Overload to a Contactor

Overloads can easily be attached to a contactor by:

(1) First disconnect all electrical power leading to the contactor.
(2) Using a Phillips head screwdriver, unscrew the five terminal screws on the right of the

contactor. These are labeled (2T1, 4T2, 6T3, 14NO and A2).

(3) Carefully place the overload unit so the five pins align with the contactor as shown below.
(4) Press the overload into the contactor until a “snap” is heard.
(5) Tighten the five terminal screws (2T1, 4T2, 6T3, 14NO and A2).
(6) Verify the overload control options (See Section 7).













9. Connecting Contactor to Controller and Loads

This section displays several methods of connection the Contactor Panel to Controllers, Power Sources
and Loads.

9.1

Evolution Stage Connections

The following diagram shows four stages connected to an Evolution Controller. Stages 1 and 2 are
contactors without overload protection. Stages 3 and 4 use overload protection.



















Evolution Stage Connections

STAGE

1

STAGE

2

STAGE

3

STAGE

4

L1

240 VAC

L2

A1

A2

A2

A1

A1

A1

Without
Overload

With
Overload

Contactor

Overload

Contactor

1 L1

3 L2

5 L3

13 A1

1410

6 T3

4 T2

2 T1

A2

2.

6

2.

2

1.

8

TEST

LR

2K

96

98

95

97

2 T1

4 T2

6 T3

H A

RE

S

E

T

Overload

Slide Overload to the left
to install

Open these screws before

inserting the overload

95

95

Manual

Operate

Switch

Advertising