Programming, Farm hand vent master 24, Program parameter listing – Hired-Hand Farm Hand Series: Vent Master 24 User Manual

Page 36: Vent master 24)

Advertising
background image

Part No. 4801-5124 rev 10-03

Farm Hand Vent Master 24

34

17. Program Parameter Listing

Farm Hand Vent Master 24





































Programming

P 1-9 Stage Programming

P1 = Stage Sensor
100= Sensor 1
020= Sensor 2
120= Average of Sensors 1 & 2
003= Sensor 3
103= Average of Sensors 1 & 3
023= Average of Sensors 2 & 3
123= Averager of Sensors 1, 2 & 3

P 20-29 Vent Machine

P20 = Vent Machine Time Delay (sec.)
P21 = Static Pressure Differential
P22 = Tunnel Target Pressure

P2 = Stage Mode
1= Heat Mode
2= Cool Stir Mode
3= Cool Neg. Mode
4= Cool Neg.Tunnel Mode
5= Cool Tunnel Mode

P 40-49 Hired Hand Network

P40 = Network Address
P41 = Software Version
P42 = Controller Setup

P3 = Timer Status
0= Stage Not On Timer
1= Stage On Timer
2= Stage is On Cool Timer

P60-69 Alarm Functions

P60 = Low Pressure Limit
P61 = High Pressure Limit

(Vent Master 24)

P25 = Tunnel "On" Temperature

PSD Room Temperature Display

100= Sensor 1
020= Sensor 2
120= Average of Sensors 1 & 2
003= Sensor 3
103= Average of Sensors 1 & 3
023= Average of Sensors 2 & 3
123= Average of Sensors 1, 2 & 3

P26 = Tunnel "Off" Temperature

PS Sensor Calibration

PS1 = Sensor 1
PS2 = Sensor 2
PS3 = Sensor 3
PS4 = Sensor 4

P30 = Ramping ON/OFF
P31 = High Temp Limit
P32 = High Temp Target Pressure
P34 = Low Temp Limit
P35 = Low Temp Target Pressure

P63 = Cycle Pressure

P70-79 Timer Settings

P70 = Cool Timer Max. Percentage
P71 = Cool Timer Min. Percentage

P 30-39 Pressure Ramping

P 10-19 Variable/Cool Timer

P10 = Min. Runtime Percentage
P11 = Motor Curve Selection

P43 = Stage Expansion
P44 = Zone Brooder Expansion