Hired-Hand Emergency Back-Up and Alarms: CONVERSION INSTRUCTIONS Alert Alarm III to Farm Hand Alert Alarm User Manual

Conversion instructions, Directions

Advertising
background image

Hired-Hand, Inc. • 1733 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-1000 • Fax 256-287-2000

Sheet Part No. 4801-5097 rev 8-02

1

2

4

3









Tools Required

Screwdriver

Small wire cutters

Wire strippers

Wire pliers

Directions

1.

Disconnect all electrical power to the Alert Alarm
controller.

2.

Unscrew front cover fastening screws. Open the
front cover of the Alert Alarm controller.

3.

Unplug the 4-pin connector (A) from the electronics
board located on inside of front cover.

4.

Carefully cut the ribbon tie (B) holding the wires to
the front cover. CAUTION! Do not cut the
wires while cutting the ribbon tie.




































5. Locate the four terminals (C) on the rear of the power

switch located on the inside front cover. There is a black
wire & a red wire that attach to the fuse holders. There is a
black wire that attaches to the 4-pin plug. There is a black
wire that attaches to the transformer. These wires are
numbered as 1,2,3,4 in the diagram below. Note and tag
each of these wires with the corresponding number
.

6. After tagging the wires (C) to the power switch, unplug

the four wires from the terminals.

7. Grasp the bent end of the metal hinge pin (D) that holds

the front cover. Slide the pin out of the hinges. Remove
the front cover. Continued On Back





CONVERSION INSTRUCTIONS

Convert Alert Alarm III to Farm Hand Alert Alarm

Warning!

Warning!

Warning!

Warning!

Disconnect All Electrical Power Sources To Controller Before Reaching Inside Unit.

Blk

Wht

Wht

Blk

Red

Blue

Blk

A

(4-pin Connector)

B

Red

Blk

C

D

Fuse

Battery

Transformer

ALERT ALARM III

NOTE:

Not all wires are shown in this diagram.

Only those wires required for installation are shown.

Electronics board

Blk

Fuse

(Battery)

(Electrical Outlet)

Advertising