9. Alarm Connections to Other Farm Hand Controllers




































N.C.

N.O.

Aux Alarm

N.C.

N.O.

Aux Alarm

This is the proper way to connect the Farm Hand family of auxillary alarm outputs to an Alert Alarm III. The
Alert Alarm III activates when the connection is broken between the Sig and Gnd terminals.

Alert Alarm III Series Alarm Connection

Note 1: As long as a path for current to flow is present, the Alert
Alarm III is not activated. Consequently, if one controller alarms,
the path will be broken and the alarm will be activated.

Aux1 or Aux 2

Sig

Gnd

Note 1

When this controller is used in a life support heating
and ventilation system where failure could result in loss
or injury, the user should provide adequate backup
ventilation or accept the risk of such loss or injury.

WARNING

ADVERTENCIA

Cuando este control se utilize en sistemas de ventilacion y

calefaccion para seres vivientes donde una falla pueda
causar una perdida o dano, el usuario debera tener sistemas
de ventilacion alternos o aceptar el riesgo de perdida o

danos.

LIMIT SETPOINTS

ALARM SOURCES

TM

Automatic Audible Alarm System

HIRED-HAND R

(PROCEDENCIA DE LA ALARMA)

(LIMITES)

POWER

TEST

(PRUEBA)

(POTENCIA)

Battery Low

Power Out

Sensor 1

Sensor 2

Auxiliary 1

Auxiliary 2

Conditions Normal

(CONDICION NORMAL)

(BATERIA BAJA)

(POTENCIA APAGADA)

(SENSOR 1)

(SENSOR 2)

(AUXILIAR 1)

(AUXILIAR 2)

LOW LIMIT

40

45

50

55

60

65

70

75

80

10

20

5

25

C

F

15

(LIMITE BAJO)

HIGH LIMIT

80

85

90

95

100

105

110

115

120

30

40

45

50

C

F

35

(LIMITE ALTO)

(PRENDIDO)

(APAGADO)

On

Off

R

R

ALERT ALARM III

ALERT ALARM III

Alarm

N.O.

N.C.

Alarm

N.C.

Com

Note 2: Remove the jumper between the
Sig and Gnd terminals when installing
external alarm inputs.

Note 2

N.O.

Advertising