Conversion

Conversion

Conversion

Conversion From Tube Motor

From Tube Motor

From Tube Motor

From Tube Motor

To Manaras Motor

To Manaras Motor

To Manaras Motor

To Manaras Motor

RS 300 Door

ROLLSEAL, INC. • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010

Manual Part No. 4801-5316

WARNING

WARNING

WARNING

WARNING

Wiring And Connections Must Comply With All National

And Local Electrical Codes. Installation By Qualified

Electrician Required!

INSTRUCTIONS:
1. Disconnect electrical power to RS 300 Door.
2. Remove cover from door. Refer to Fig. 1.




















3. Remove

curtain

panel.

4. Unclip Somfy tube motor from end plate bearing.
5. Remove end plate from top assembly.

6. Slide tube motor out of drive pipe as shown in Fig. 2.











7. Cut 1 5/8” off from the Drive Pipe as shown in Fig. 2.
8. Insert Manaras drive shaft assembly into drive pipe as

shown in Fig. 3abc.

9. Drill four holes (3/16" dia.) around drive pipe for

mounting with 3/16" stainless steel pop rivets as shown in
Fig. 4. Space holes evenly around drive pipe.

WARNING

WARNING

WARNING

WARNING

Disconnect All Electrical Power Sources To RS 300 Door

Before Installation Of Replacement Motor!


































10. Install 3/16" stainless steel pop rivets to drive pipe as

shown in Fig. 5








!

!

FIG. 3

FIG. 4

Install 3/16" stainless
steel pop rivets

FIG. 5

FIG. 1

Exploded View

Of Top Assembly

Cover

Tube
Motor Mount

Curtain panel

NEW End
Plate Bearing

FIG. 2

Drive Pipe

Cut 1 5/8”