TROUBLESHOOTING

D-4

IDEALARC® R3R, -300, -400, -500

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

FUNCTION PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine does not have maximum
output (67 to 71 volts).

Machine comes on but soon trips
off while under load and High
Temperature Warning Light glows.
(Thermostat tripped)

Machine comes on but reduces to
low output under load and remains
there until the load is broken and
arc re-started. See Fault Protection
Operation Section.

1. Input fuse blown. Machine is

single phased.

2. One phase of main transformer

windings open.

3. Defective power bridge.

1. Improper ventilation.

2. Loaded beyond rating.

3. Fan inoperative.

4. Shorted diode or SCR in power

rectifier bridge.

1. Excessive load causing the over-

load protection on control board
to operate.

2. Machine output shorted causing

overload protection on control
board to operate.

3. Control circuit defective.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.