Installation, Square wave tig 275, Input phase single – Lincoln Electric IM609 SQUARE WAVE TIG 275 User Manual

Page 13: Single phase input

Advertising
background image

A-6

INSTALLATION

SQUARE WAVE TIG 275

A-6

575V

460V

WARNING:

Powered by high voltage which can kill. Turn off all input

Connect the input power leads to the input terminals, L1 (U) and L2 (V), at the right
below. Connect the input power leads with the hardware provided. Completely
tighten all fasteners.

Connect a grounding lead to the ground stud located on the machine base near
the input terminals.

Welders are shipped connected for the highest rated single phase input voltage
with the lead marked "A" connected to the stud marked "4 (HIGH)".

For middle range input, reconnect the lead marked "A" to the stud marked "3 (MID)".

For low range input, reconnect the lead marked "A" to the stud marked "2 (LOW)".

power at the disconnect switch or fuse box before making any connections. Use
input and grounding lead sizes as specified in the operating manual. Failure to follow
instructions below can cause immediate failure of components within the welder.

SINGLE PHASE INPUT POWER SUPPLY CONNECTION INSTRUCTIONS:

2.

3 (MID)

2 (LOW)

L2 (V)

L1 (U)

5.

4.

3.

LEADS FOR OPTIONAL

POWER FACTOR CAPACITORS

4 (HIGH)

INPUT

PHASE

SINGLE

1.

460/575 CANADIAN MODEL

Figure A.3

Reconnect Panel Instructions for 460/575 Canadian Model

415V

380V

220V

1. Connect the input power leads to the input terminals, L1 (U) and L2 (V), at the right

below. Connect the input power leads with the hardware provided. Completely
tighten all fasteners.

Connect a grounding lead to the ground stud located on the machine base near
the input terminals.

Welders are shipped connected for the highest rated single phase input voltage
with the lead marked "A" connected to the stud marked "4 (HIGH)".

For middle range input, reconnect the lead marked "A" to the stud marked "3 (MID)".

For low range input, reconnect the lead marked "A" to the stud marked "2 (LOW)".

Powered by high voltage which can kill. Turn off all input

power at the disconnect switch or fuse box before making any connections. Use
input and grounding lead sizes as specified in the operating manual. Failure to follow
instructions below can cause immediate failure of components within the welder.

WARNING:

SINGLE PHASE INPUT POWER SUPPLY CONNECTION INSTRUCTIONS:

5.

4.

3.

2.

LEADS FOR OPTIONAL

L2 (V)

L1 (U)

2 (LOW)

3 (MID)

4 (HIGH)

SINGLE

PHASE

INPUT

POWER FACTOR CAPACITORS

220/380/415 EUROPEAN MODEL

Figure A.4

Reconnect Panel Instructions for 220/380/415 European Model