Installation, Technical specifications – dc-400 – Lincoln Electric IM655 RED-D-ARC DC-400 User Manual

Page 9

Advertising
background image

A-1

INSTALLATION

DC-400

A-1

TECHNICAL SPECIFICATIONS – DC-400

Standard

Input Current at Rated Output (CVI)

Voltage

100% Duty Cycle 60% Duty Cycle

(4)

50% Duty Cycle

Frequency

230/460/575V/60Hz

400Amps/36V

450Amps/38V 500Amps/40V

78/39/31Amps 83/42/33Amps 84/42/34Amps

INPUT-THREE PHASE ONLY

RATED OUTPUT

HEIGHT WIDTH

DEPTH

WEIGHT

27.50 in.

22.25 in.

32.0 in.

473 lbs.

699 mm

565 mm

988 mm

215 kg.

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

Duty Cycle

(1)

Amps

Volts at Rated Amps

100% 400

36

60%

450

38

50%

500

40

OUTPUT

MAXIMUM OPEN CIRCUIT VOLTAGE

AUXILIARY POWER

Min.----60A 12V CV(22V CC) 57V. (CC) 45.5V. (CVI)

115 VAC, 15 AMPS

Max.---500A 42V (CC, CV)

42 VAC, 10 AMPS

PHYSICAL DIMENSIONS

(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on an 4 minutes off).

INPUT

VOLTAGE /

FREQUENCY

230/60HZ
460/60HZ
575/60HZ

INPUT AMPERE

RATING ON

NAMEPLATE

@ 100%

Duty Cycle

78
39
31

TYPE 75°C COPPER

WIRE IN CONDUIT

AWG (IEC)

SIZES (mm

2

)

40°C(104°F)

3(25)
8(10)
10(6)

TYPE 75°C GROUND

WIRE IN CONDUIT

AWG (IEC)

SIZES (mm

2

)

6(10)
10(6)
10(6)

TYPE 75°C

SUPER LAG

OR BREAKER

SIZE(AMPS)

125

60
50

Advertising