OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

No output - Main input fuses open,
indicating excessive current draw.

The machine operates normally
when connected for 200 - 230VAC
input. There is no output when the
machine is connected to 380VAC or
higher.

1. Inspect input leads for possible

shorts or grounds or mis-connec-
tions.

2. Install new fuses and reapply

power. If fuses open again, con-
sult a Lincoln Authorized Field
Service Facility.

1. Check the input voltage and input

voltage reconnect procedures.
See

Installation Section

of this

manual.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.