Installation – Lincoln Electric IM847 LF-72 WIRE FEEDER User Manual

Page 22

Advertising
background image

A-14

INSTALLATION

LF-72

A-14

SHIELDING GAS CONNECTION

CYLINDER may explode if damaged.

• Keep cylinder upright and chained to

support.

• Keep cylinder away from areas

where it may be damaged.

• Never lift welder with cylinder attached.
• Never allow welding electrode to touch cylinder.
• Keep cylinder away from welding or other live

electrical circuits.

------------------------------------------------------------------------

BUILD-UP OF SHIELDING GAS may
harm health or kill.

• Shut off shielding gas supply when

not in use.

SEE AMERICAN NATIONAL STANDARD Z-49.1,
"SAFETY IN WELDING AND CUTTING" PUB-
LISHED BY THE AMERICAN WELDING SOCIETY.
------------------------------------------------------------------------
Maximum inlet pressure is 100 psi. (6.9 bar.)

Install the shielding gas supply as follows:

1. Secure the cylinder to prevent it from falling.

2. Remove the cylinder cap. Inspect the cylinder

valves and regulator for damaged threads, dirt,
dust, oil or grease. Remove dust and dirt with a
clean cloth. DO NOT ATTACH THE REGULATOR
IF OIL, GREASE OR DAMAGE IS PRESENT!
Inform your gas supplier of this condition. Oil or
grease in the presence of high pressure oxygen is
explosive.

3. Stand to one side away from the outlet and open

the cylinder valve for an instant. This blows away
any dust or dirt which may have accumulated in the
valve outlet.

4. Attach the flow regulator to the cylinder valve and

tighten the union nut(s) securely with a wrench.
Note: If connecting to 100% CO

2

cylinder, insert

regulator adapter between regulator and cylinder
valve. If adapter is equipped with a plastic washer,
be sure it is seated for connection to the CO

2

cylin-

der.

5. Attach one end of the inlet hose to the outlet fitting

of the flow regulator. Attach the other end to the
welding system shielding gas inlet. Tighten the
union nuts with a wrench.

6. Before opening the cylinder valve, turn the regulator

adjusting knob counterclockwise until the adjusting
spring pressure is released.

7. Standing to one side, open the cylinder valve slowly

a fraction of a turn. When the cylinder pressure
gage stops moving, open the valve fully.

8. The flow regulator is adjustable. Adjust it to the flow

rate recommended for the procedure and process
being used before making a weld.

Advertising