Diagrams, Mobiflex 200-m – Lincoln Electric IM621 Mobiflex 200-M K1653-1,-2 User Manual

Page 21

Advertising
background image

E-3

DIAGRAMS

E-3

MObIFLEX 200-M

1L1

3L2

5L3

1/L1

3/L2

5/L3

2/T1

4/T2

6/T3

1

2

3

4

5

6

13

14

2T1

4T2

6T3

A1

TR 188.83

SERIE: 9740

0 115V 230V 400V
Primair

SEC. 24V

48VA

A2

BN

BK
BN
BL

BN

BL

BL

BN

BN

WH

WH

WH

BN

BN

BN

BN

BN

GN

GN

GN

GN

BK

BK

W

H

B

N

G

N

N.A.

N.A.

N.B.

N.B.

N.B.

N.A. MOUNT ON DIN RAIL.

N.C.

10

13
16

STOP

START

STARTER/OL

TRANSFORMER

FUSE

TERMINAL
BLOCK

A

A

N.D.

W

1

U

1

V1

U

2

V2

W

2

MOTOR

FA

N

M

O

TO

R

GND

INPUT POWER
115V/1PH/60HZ

L
N
GND

GN

BN

WH

W

H

B

N

G

N

WH

BN

GN

BK
BK

LA

M

P
I/O

WORK LAMP

AUTO START/STOP
ARC SENSOR

R

EM

O

TE

S

W

IT

C

H

LAMP

B

L

B

N

G

N

D

GND

BN

BL

N.E.

WH

BN

GN

GND

GND

CONTROL PANEL - MOBIFLEX BASE UNIT

WIRE COLOR CONVENTIONS

BN - Brown
BL - Blue
BK - Black
GN - Green
WH - White
GND - Green/Yellow

GN
BN

WH

WH

BN

GN

13 FT. CONNECTION CABLE

N.E.

N.E.

N.E.

NOTES:

BN
BL

N.B. MOUNT WITH SELF-TAPPING SCREWS ON MARKED MOUNTING HOLES PER
INSTALLATION SECTION.
N.C. TO INSERT CONDUCTORS IN TERMINAL BLOCK, PUSH IN ON FRONT OPENING
WITH SMALL SCREWDRIVER, AND INSERT WIRE IN CORRESPONDING
TOP OPENING.
N.D. PLACE STICKER ON MOUNTING SURFACE BEHIND TERMINAL BLOCK SO THAT
THE CENTERING LINES ALMOST COVER THE MOUNTING POINTS OF THE
TERMINAL BLOCK.
N.E. CONNECTIONS TO INPUT PLUG AND FAN MOTOR ARE INTERNAL TO THE
MOBIFLEX BASE UNIT. STANDARD 115V PLUG AND 15 FT. (5M) INPUT CORD
PROVIDED.
N.F. LAMP WIRES ARE WHITE WITH BLACK SLEEVES.

N.F.

N.F.

CONTACTOR

L

N

START
CAPACITOR

1L1

3L2

5L3

1/L1

3/L2

5/L3

2/T1

4/T2

6/T3

1

2

3

4

5

6

13

14

2T1

4T2

6T3

A1

TR 188.83

SERIE: 9740

0 115V 230V 400V

Primair

SEC. 24V

48VA

A2

BN

BK

BN

BL

BN

BL

BL

BN

BN

WH

WH

WH

BN

BN

BN

BN

BN

GN

GN

GN

GN

BK

BK

W

H

B

N

G

N

N.A.

N.A.

N.B.

N.B.

N.B.

N.A. MOUNT ON DIN RAIL.

N.C.

10

1

3

16

STOP

START

STARTER/OL

TRANSFORMER

FUSE

TERMINAL

BLOCK

A

A

N.D.

W

1

U

1

V

1
U

2

V

2

W

2

MOTOR

F

A

N

M

O

T

O

R

GND

INPUT POWER

115V/1PH/60HZ

L
N

GND

GN

BN

WH

W

H

B

N

G

N

WH

BN

GN

BK
BK

L

A

M

P

I/

O

WORK LAMP

AUTO START/STOP

ARC SENSOR

R

E

M

O

T

E

S

W

IT

C

H

LAMP

B

L

B

N

G

N

D

GND

BN

BL

N.E.

WH

BN

GN

GND

GND

CONTROL PANEL - MOBIFLEX BASE UNIT

WIRE COLOR CONVENTIONS

BN - Brown
BL - Blue
BK - Black
GN - Green
WH - White
GND - Green/Yellow

GN

BN

WH

WH

BN

GN

13 FT. CONNECTION CABLE

N.E.

N.E.

N.E.

NOTES:

BN

BL

N.B. MOUNT WITH SELF-TAPPING SCREWS ON MARKED MOUNTING HOLES PER
INSTALLATION SECTION.
N.C. TO INSERT CONDUCTORS IN TERMINAL BLOCK, PUSH IN ON FRONT OPENING
WITH SMALL SCREWDRIVER, AND INSERT WIRE IN CORRESPONDING
TOP OPENING.
N.D. PLACE STICKER ON MOUNTING SURFACE BEHIND TERMINAL BLOCK SO THAT
THE CENTERING LINES ALMOST COVER THE MOUNTING POINTS OF THE
TERMINAL BLOCK.
N.E. CONNECTIONS TO INPUT PLUG AND FAN MOTOR ARE INTERNAL TO THE
MOBIFLEX BASE UNIT. STANDARD 115V PLUG AND 15 FT. (5M) INPUT CORD
PROVIDED.
N.F. LAMP WIRES ARE WHITE WITH BLACK SLEEVES.

N.F.

N.F.

CONTACTOR

L

N

START
CAPACITOR

WIRING DIAGRAM FOR MObIFLEX 2OO-M WITH LAMP

OPTION

AND

ARC SENSOR

S23315-2