Operation, B-10, B-10 weld process adjustments – Lincoln Electric IM848 POWER WAVE AC_DC 1000 User Manual

Page 48: Ac adjustments, Wave balance, Dc offset, Frequency

Advertising
background image

B-10

OPERATION

B-10

WELD PROCESS ADJUSTMENTS

Depending on the weld mode, there are a number of
adjustments that can be made, including but not limit-
ed to Current, Voltage and WFS. These adjustments
apply to either AC or DC processes, and control the
basic parameters of the weld.

AC ADJUSTMENTS

In addition to the basic weld parameters, there are a
number of unique adjustments related to the AC
waveform of the Power Wave AC/DC 1000. These
adjustments enable the operator to balance the rela-
tionship between penetration and deposition to tailor
the output for specific applications.

WAVE BALANCE

• Refers to amount of time the waveform spends in

DC+ portion of the cycle.

• Use Wave Balance to control the penetration and

deposition of a given process.

DC OFFSET

• Refers to +/- shift of the current waveform with

respect to the zero crossing.

• Use Offset to control the penetration and deposition

of a given process.

FREQUENCY

• POWER WAVE AC/DC 1000 can produce Output

Frequencies from 10 - 100Hz

• Use Frequency to fine tune stability
• Higher frequencies in multiple arc setups can help

reduce arc interaction

POWER WAVE® AC/DC 1000

500

-500

0

-1000

1000

Nominal Balance

Increased Balance

More Penetration

Less Deposition

Decreased Balance

Less Penetration

More Deposition

Wave Balance

500

-500

0

-1000

1000

Use Frequency to fin e tune stabilit y of

imb alanced waveform s and multipl e arc syst ems

Frequency

Increase

Decrease

500

-500

0

-1000

1000

Nominal Offset

Positive Offset

More Penetration

Less Deposition

Negative Offset

Less Penetration

More Deposition

DC Offset

Advertising