POWER WAVE

®

C300

EXAMPLE 1 - 2 STEP TRIGGER: Simple operation
The simplest trigger operation occurs with a 2 Step
trigger and the Start, Crater and Burnback functions
all set to OFF. (See Figure B.11)

For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.

RUN-IN:
After preflow time expires, the power source regulates
to the welding output and wire is advanced towards
the work piece at the Run-In WFS. If an arc is not
established within 1.5 seconds, the wire feed speed
will jump to the welding wire feed speed

WELD:
The power source output and the wire feed speed
continue at the weld settings for as long as the trigger
is pulled.

POSTFLOW:

As soon as the trigger is released, the

power source output and the wire feed speed are
turned OFF. Shielding gas continues until the post
flow timer expires.

Shielding
Gas

Idle

Preflow

Run-In

Weld

Pos tflow

Idle

Power
Source
Output

WFS

O n

O ff

Run- in

O ff

Wel d

O ff

Wel d

Arc

Established

T

rigger

Pulled

T

rigger

Released

2 Step Tri gger
Start = OFF
Crater = OFF
Burnback = OFF

1.5 sec max.

FIGURE B.11