E-3

TROUBLESHOOTING

E-3

RED-D-ARC E300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Welder will not weld.

Welder welds, but soon stops weld-
ing (DC only).

1. Line switch not turned “On”.

Supply line fuse blown.

2. Power circuit dead.

3. Broken power lead.

4. Wrong voltage.

5. Electrode or work lead loose or

broken.

6. Open transformer circuit.

1. Proper ventilation hindered.

2. Welder loaded beyond rating.

3. Fan motor inoperative.

4. Poor internal connections.

5. Excessive dust accumulation in

welder.

6. Bi-metallic thermostat dirty.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.