Diagrams, Input connection diagram, Synergic 7 & 7h – Lincoln Electric IM558 Synergic 7 and 7H Water Cooled User Manual

Page 45: Warning

Advertising
background image

F-2

DIAGRAMS

F-2

SYNERGIC 7 & 7H

E=GND

F=67

8-PIN BOX RECEPTACLE, FRONT VIEW

M=81

C=2

N=67

H=82

D=4

14-SOCKET BOX RECEPTACLE, FRONT VIEW

G=81

AND 14-PIN CABLE PLUG, REAR VIEW

B=GND

I=41

TRIGGER CIRCUIT

2

GND

L

4

N

I

PIN

ELECTRODE CABLE

42

D

PLUG

PIN#

TRIGGER CIRCUIT

41

C

FUNCTION

42V AC

+SERIAL COMM LOOP

-SERIAL COMM LOOP

14

81

67

LEAD

K

82

M

ELECTRODE

B

42V AC

POWER SOURCE TO WIRE FEEDER CABLE

GROUNDING LEAD

TO WORK

AND 8-SOCKET CABLE PLUG, REAR VIEW

G

F

A

S21041-1

ON POWER SOURCE TO PROPER POLARITY.

POWER SOURCE AND SET-UP PROCEDURE

CHANGE POLARITY, TURN POWER "OFF",

REVERSE ELECTRODE AND WORK CABLES AT

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO

WARNING

AND FUTURE DUTY CYCLE OF APPLICATION.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT

service this machine.

Only qualified persons should install, use or

Turn OFF the power switch on the Welding

Power Source before connecting the wire feeder.

C

D

A

B

H

E

PIN#

D=4

B=42

A=41

C=2

PLUG

PIN

8

L=82

K=42

PRESENT IN YOUR EQUIPMENT.

(SEE APPROPRIATE WIRING DIAGRAM)

IN CABLE.

ONLY AND EACH MAY OR MAY NOT BE

FUNCTIONS ARE LISTED FOR REFERENCE

N.C. PINS NOT LISTED ARE NOT CONNECTED

CAN KILL

SHOCK

ELECTRIC

INPUT CONNECTION DIAGRAM