High off low, Air inflation and confined space-cleaning, Warning – Rainbow e2 (Silver) User Manual

Page 8: For normal cleaning operations and air cleaning, Rinsing the hepa neutralizer warning

Advertising
background image

AIR INFLATION AND CONFINED SPACE-CLEANING:

This unique Rainbow tool provides users with

the added convenience of two specialized

capabilities: air infl ation and confi ned-space

cleaning.

The

Rainbow Infl ator is the ideal tool for

Infl ator

Infl ator

conveniently infl ating beach balls, infl atable

toys and air mattresses.

The

Rainbow Confi ned-Space Cleaner

is the ideal tool for cleaning hard-to-get-

at areas like refrigerator coils, behind and

under appliances, cabinets or furniture. Coil

cleaner extension can be used in either

suction or blower mode (see illustration).

The

Rainbow Airfl ow Adaptor is used to

ow Adaptor

ow Adaptor

reduce air noise through the air inlet. It is

recommended to use the adaptor when the Rainbow is used as a blower. Simply

snap the Airfl ow Adaptor into the air inlet opening before using the Rainbow

as a blower.

Instructions For Use: To use the Rainbow Infl ator, open the exhaust vent door at

the back of the power unit. Attach the hose to the exhaust opening. Attach Rainbow

curved wand handle to the hose and the infl ator to the handle. Secure the connection

with the button lock. The infl ator pin is then inserted into the tool body. Twist one-

half turn counter-clockwise to lock pin in place. Insert the pin into the infl ator stem of

the object to be infl ated and turn on the power unit. Also, use the Airfl ow Adaptor to

reduce air noise through the air inlet opening during this operation.

AIR

CLEANING

AIR INFLATION

AND CONFINED-

SPACE CLEANING
NOTE:

When using the Rainbow

as an air cleaner,

remove attachments.

The Rainbow is equipped

with low and high speed.

WARNING:

Be sure infl ator pin is

properly locked in place.

If not, it will be blown

forcefully from the

tool body.

FOR NORMAL CLEANING OPERATIONS AND
AIR CLEANING:

Select high-speed setting for maximum

cleaning performance. Low speed can

also be used for air cleaning.
Air Cleaner - The Rainbow cleans the

air you breathe. The air in the average

home contains large amounts of dust,

lint and other foreign substances. Run

your Rainbow without attachments in

any desired area for about an hour

every day. The Rainbow takes the dust

from the air and drowns it in the water.
Humidifi er - In the winter, the air in

the average home often becomes

excessively dry. Run your Rainbow

without attachments to humidify the air you breathe. Using your Rainbow in this

manner daily will help maintain the proper humidity.
Deodorizer / Aromatizer - By adding a few drops of your favorite Rainbow fragrance

Deodorizer / Aromatizer

Deodorizer / Aromatizer

or Rainbow Deodorant Air Freshener to the water while running your Rainbow

without the attachments, the air is quickly freshened and objectionable household

odors removed.
Vaporizer - Place a few drops of an inhalant in the water of your Rainbow basin. Run

Vaporizer

Vaporizer

the Rainbow without attachments and breathe deeply.

HIGH

OFF

LOW

1

REMOVE THE REAR PANEL:
Using a screwdriver, remove

the panel from the back of the

Rainbow by pressing up on the

two latches on the underside of

the rear panel. Move the bottom

of the rear panel towards you,

lifting up.

RINSING

THE HEPA

NEUTRALIZER

WARNING:

Unplug the Rainbow

before servicing.

Do not operate the

Rainbow without the

HEPA Neutralizer.

NOTE:

Do not use detergent or

soap to wash the fi lter.

Use clean water only.

3

RINSING THE HEPA NEUTRALIZER:

A

Place the dirty HEPA Neutralizer in the sink

with the oval opening facing up.

B Fill the oval opening in the HEPA Neutralizer

with cool water from a faucet until the water

comes out of the opening. Continue to let

the water run over the HEPA Neutralizer for

approximately one minute.

C Turn off the water supply. Turn the HEPA

Neutralizer over and tap into the sink so that

the water escapes from the oval opening.

D Repeat steps B and C until no substantial

amount of dirt is seen coming out of

the HEPA Neutralizer. Shake the HEPA

Neutralizer briskly, with oval opening facing

down, to remove any excess water.

E Reinstall the HEPA Neutralizer and rear

panel by following the instructions in

reverse order.

2

REMOVE THE HEPA NEUTRALIZER.

4

DRYING THE HEPA NEUTRALIZER:

A Make sure the vent door is removed

from the rear panel.

B With the water basin empty, set the

Rainbow on the edge of a towel or

other absorbent cloth, such that the

vent door side of the Rainbow is facing

the cloth or towel.

C Install the airfl ow adapter onto the front

of the Rainbow to dampen noise.

D Run the Rainbow on high speed for

approximately 1/2-hour to thoroughly

dry the HEPA Neutralizer.

E Excess water from the rinsing process

may be emitted onto the towel or

absorbent cloth during the fi rst portion

of the 1/2-hour drying time.

F After the HEPA Neutralizer is dry,

replace the vent door.

G If cleaning ability is not adequately

restored

after

the

HEPA

Neutralizer is dry, contact your

Authorized Distributor.