Storage for the “L” wrenches is provided for quick

access when adjustments are needed.

Place the (4) “L” wrenches (3mm, 4mm, 5mm and 6mm)

in the tool holder on the rear column support (Fig.13).

Setting the Table Square to Saw Blade

The table may be set at 90° to the saw blade sides

by adjusting the table stop screw under the table. The

table stop screw rests on the top of the quick release

adjustment stop. By first loosening the locking nut

(A-Fig.14) and then adjusting the screw (B-Fig.14), the

table can be set correctly. Retighten the locking nut

(A-Fig.14) making sure that the setting is maintained.

The table may also be set at 90° to the back of the saw

blade by adjusting the four trunnion micro adjustment

screws (A-Fig.15). First, slightly loosen part #98 (refer to

parts explosion on page 18

of this manual). Using the

3mm “L” wrench, turn the rear trunnion micro adjusting

screws part #125. Turning the screws clockwise will

raise the trunnion; counterclockwise will lower. Check

table for 90° and tighten part #98.

(Trunnion has been removed from bandsaw for clarity. Micro

adjusting screws are raised to exaggerate location. Only two of the

four micro adjusting screws shown.)

Tilting the Table

Loosen the lock handle (A-Fig.16) on the table trunnion.

Turn the table tilting knob (B-Fig.16) to adjust the table

to the desired angle. Use the angle indicator scale on

the trunnion bracket to find the desired angle. Retighten

the lock handle to secure the table.

Assembly

Figure 13

11

Figure 14

Tool Holder

Adjustments

A

B

Figure 15

Figure 16

A

B

A