Pilot valve assembly – SANDPIPER SA25 User Manual

Page 16

Advertising
background image

sa1dl5sm-rev0614

sandpiperpump

.

com

13

• Model SA1/SA25

Pilot Valve Assembly

ATEX Compliant

PILOT VALVE ASSEMBLY PARTS LIST

Item

Part Number

Description

Qty

3

095.074.001

Pilot Valve Assembly

1

3A

095.071.557

Pilot Valve Body

1

3B

755.025.162

Pilot Valve sleeve

1

3C

560.033.360

O-Ring

4

3D

775.014.115

Pilot Valve Spool

1

3E

560.023.360

O-Ring

4

3F

675.037.050

Retaining Ring

1

Pilot Valve Servicing

With Pilot Valve removed from pump.
Step 1: Remove snap ring (3F).
Step 2: Remove sleeve (3B), inspect O-Rings (3C),

replace if required.

Step 3: Remove spool (3D) from sleeve (3B),

inspect O-Rings (3E), replace if required.

Step 4: Lightly lubricate O-Rings (3C) and (3E).
Reassemble in reverse order.

3F

3A

3D

3B

3C

3E

LEGEND:
= Items contained within Air End Kits

MODEL SPECIFIC

4: AIR

END

Advertising
This manual is related to the following products:

SA1