background image

s20nmdl3sm-rev0614

sandpiperpump

.

com

Model S20 Non-Metallic •

20

Leak Detection Options Drawing

LEAK DETECTION OPTION (ELECTRONIC)

Follow instructions found elsewhere in this manual,

“Filling the Spill Prevention Chambers” when installing

leak detectors.

Electronic Leak Detector Installation

Kit 032-037-000

100VAC

50Hz

or

110-120VAC

50/60Hz

or 220-240VAC

50/60Hz

Kit 032-045-000

12-32VDC

To install electronic leak detectors, remove the bottom

¼" NPT pipe plug on the visual sight tube (item 50). Insert

leak detector into the ¼" pipe tee (item 53).

LEAK DETECTION OPTION (MECHANICAL)

Follow instructions found elsewhere in this manual,

“Filling the Spill Containment Chambers” when installing

leak detectors.

Mechanical Leak Detector Installation

Kit 031-023-110

To install mechanical leak detectors, remove the bottom

¼" NPT pipe plug on the visual sight tube (item 50). Insert

leak detector into the ¼" pipe tee (item 53).

6: OPTIONAL