Airvantage troubleshooting continued – SANDPIPER RS30 Metallic User Manual

Page 13

Advertising
background image

rs30mdl1sm-rev0614

Model RS30 Metallic Page 11

AirVantage Troubleshooting Continued

AirVantage RESETS AND ENTERS LEARN MODE TOO FREQUENTLY

What to Check:

• Check for excessive varying environmental pumping conditions

(changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

• Make sure patch cable plug is connected and locked

Corrective Action:

• Consult Factory After Sales Support Team

PUMP STALLS, RESETS, LEARNS, SEEKS AND REPEATS

What to Check:

• Make sure patch cable plug is connected and locked

• Check ice buildup in exhaust area

Corrective Action:

• Consult Factory After Sales Support Team

PUMP MOVES OUT OF STEADY STATE AND NEVER

ATTEMPTS TO RELEARN (LED ON)

What to Check:

• Make sure patch cable plug is connected and locked

• Cycle the power off/on to the control module

Corrective Action:

• Consult Factory After Sales Support Team

• Cycle the power switch on the control module off/on

WHAT TO DO IN THE EVENT OF A DIAPHRAGM FAILURE

If a diaphragm failure has been detected in pumps fitted with AirVantage,

see page 5 for shut-down procedure.

What to Check:

• Has product migrated to the sensor?

Corrective Action:

• If the sensor has been submerged in product, the sensor will need to be

replaced. Consult the AirVantage servicing section of the manual for detailed instructions.

What to Check:

• Has product contaminated the check valve cartridge?

Correct Action:

• If a significant amount of product has made it into the check valve assembly, then the unit will need to

be disassembled for inspection. If the check valve assembly is damaged, then it will need to be replaced.

Consult parts list for information.

SEAL, O-RING

(Purchased Separately)

VALVE, POPPET

VALVE, SOLENOID

CAPSCREW, HEX SOC HD, 10-32 X .50

COVER

SEAL, O-RING

SEAL, O-RING

MUFFLER

SEAL, O-RING

ASSEMBLY, POWER GENERATOR

CAPSCREW, HEX SOC HD, 10-32 X 2.25

CAPSCREW, HEX SOC HD, 10-32 X 1.00

CAPSCREW, HEX SOC HD, 10-32 X .50

O-RING

O-RING

CONTROL MODULE

REGULATOR

Optional 1/4" NPT Pipe Plug (P/N 618.011.330)

Must be installed if performing direct spray

wash-down of pump

Advertising