rs20mdl1sm_haz duty-rev0614

Model RS20 Hazardous Duty Metallic Page 21

PULSE OUTPUT KIT OPTION

This pump can be fitted with a Pulse Output Kit. This converts the mechanical strokes of the

pump to an electrical signal which interfaces with the Stroke Counter/ Batch Controller or user

control devices such as a PLC.

The Pulse Output Kits mount directly onto the Muffler Cap on the Air Distribution Valve Assembly

or onto the air valve and senses each stroke of the main spool.

Consult the factory for further information and availability.

Pulse Output Kit Drawing

Pulse Output Kits

475-244-003

10-30VDC, 110VAC and 220 VAC

Intrisincally Safe

5-30 VDC, 110-120VAC, 220-240VAC