Model EB1-SM Type 3 Page 5

WARNING

BEFORE PUMP OPERATION all
external gasketed fasteners must
be inspected for looseness caused
by gasket creep after leaving the
factory. Retorque loose fasteners
to insure against leakage. Follow
recommended torques where called
out. (A card is attached to each new
pump stating this fact.)

IMPORTANT

This pump is pressurized internally
with air pressure during operation.
Always make certain that all bolting
is in good condition and that all of
the correct bolting is reinstalled
during assembly.

Optional freestanding base

B. Make certain the suction line or strainer is not plugged. Restriction at the suction is
indicated by a high vacuum reading when a vacuum gauge is installed in the suction line.
C. Check valves may not be seating properly. To check, remove the suction line and
cover the suction port with your hand. If the unit does not pull a good suction (vacuum),
the check valves should be inspected for proper seating.
D. Static suction lift may be too high. Priming can be improved by elevating the suction
and discharge lines higher than the check valves and pouring liquid into the unit through
the suction inlet. When priming at high suction lifts or with long suction lines operate the
pump at maximum cycle rate.
3. Low performance
A. Capacity is reduced as the discharge pressure increases, as indicated on the
performance curve. Performance capability varies with available inlet air supply. Check
air pressure at the pump inlet when the pump is operating to make certain that adequate
air supply is maintained.
B. Check vacuum at the pump suction. Capacity is reduced as vacuum increases.
Reduced flow rate due to starved suction will be evident when cycle rate can be varied
without change in capacity. This condition will be more prevalent when pumping viscous
liquids. When pumping thick, heavy materials the suction line must be kept as large in
diameter and as short as possible, to keep suction loss minimal.
C. Low flow rate and slow cycling rate indicate restricted flow through the discharge line.
Low flow rate and fast cycling rate indicate restriction in the suction line or air leakage
into suction.
D. Unstable cycling indicates improper check valve seating on one chamber. This
condition is confirmed when unstable cycling repeats consistently on alternate ex-
hausts. Cycling that is not consistently unstable may indicate partial exhaust restriction
due to freezing and thawing of exhaust air. Use of an anti-freeze lubricant in an air line
lubricator should solve this problem.

For additional information, see the Warren Rupp Troubleshooting Guide.

WARRANTY

This pump is warranted for a period of five years against defective material and

workmanship. Failure to comply with the recommendations stated in this manual voids
all factory warranty.

RECOMMENDED WARREN RUPP ACCESSORIES TO

MAXIMIZE PUMP PERFORMANCE:

• Tranquilizer

®

Surge Suppressor: For nearly pulse-free flow.

• Warren Rupp Filter/Regulator: For modular installation and service

convenience.

• Warren Rupp Speed Control: For manual or programmable process

control. (Manual adjustment or 4-20mA reception.)

For more detailed information on these accessories, contact your local Warren
Rupp Factory-Authorized Distributor, or Warren Rupp corporate headquarters.