SANDPIPER EB1-M User Manual

Page 2

Advertising
background image

WARNING

Take action to prevent static sparking.
Fire or explosion can result, especially
when handling flammable liquids. The
pump, piping, valves, containers or other
miscellaneous equipment must be
grounded.

BEFORE OPERATION

Before pump operation, inspect all
gasketed fasteners for looseness caused
by gasket creep. Retorque loose fasten-
ers to prevent leakage. Follow recom-
mended torques stated in the card at-
tached to the new pump.

Model EB1-M

Page 2

520-031-000

8/00

A NOTE ABOUT AIR VALVE LUBRICATION

The SandPIPER pump’s pilot valve and main air valve assemblies are designed

to operate WITHOUT lubrication. This is the preferred mode of operation. There may
be instances of personal preference, or poor quality air supplies when lubrication of
the compressed air supply is required. The pump air system will operate with properly
lubricated compressed air supplies. Proper lubrication of the compressed air supply
would entail the use of an air line lubricator (available from Warren Rupp) set to deliver
one drop of 10 wt., non-detergent oil for every 20 SCFM of air the pump consumed at
its point of operation. Consult the pump’s published Performance Curve to determine
this.

It is important to remember to inspect the sleeve and spool set routinely. It should

move back and forth freely. This is most important when the air supply is lubricated.
If a lubricator is used, oil accumulation will, over time, collect any debris from the
compressed air. This can prevent the pump from operating properly.

Water in the compressed air supply can create problems such as icing or freezing

of the exhaust air causing the pump to cycle erratically, or stop operating. This can be
addressed by using a point of use air dryer to supplement a plant’s air drying
equipment. This device will remove excess water from the compressed air supply and
alleviate the icing or freezing problem.

ESADS: Externally Serviceable Air Distribution System

Please refer to the exploded view drawing and parts list in the Service Manual

supplied with your pump. If you need replacement or additional copies, contact your
local Warren Rupp Distributor, or the Warren Rupp factory Literature Department at
the number shown on page one. To receive the correct manual, you must specify the
MODEL and TYPE information found on the name plate of the pump.

MODELS WITH 1" SUCTION/DISCHARGE OR LARGER,
AND NON-METAL CENTER SECTIONS

The main air valve sleeve and spool set is located in the valve body mounted on

the pump with four hex head capscrews. The valve body assembly is removed from
the pump by removing these four hex head capscrews.

With the valve body assembly off the pump, access to the sleeve and spool set is

made by removing a retaining ring (each end) securing the end cap on the valve body
assembly. With the end caps removed, slide the spool back and forth in the sleeve.
The spool is closely sized to the sleeve and must move freely to allow for proper pump
operation. An accumulation of oil, dirt or other contaminants from the pump’s air
supply, or from a failed diaphragm, may prevent the spool from moving freely. This can
cause the spool to stick in a position that prevents the pump from operating. If this is
the case, the sleeve and spool set should be removed from the valve body for cleaning
and further inspection.

Remove the spool from the sleeve. Using an arbor press or bench vise (with an

improvised mandrel), press the sleeve from the valve body. Take care not to damage
the sleeve. At this point, inspect the o-rings on the sleeve for nicks, tears or abrasions.
Damage of this sort could happen during assembly or servicing. A sheared or cut o-
ring can allow the pump’s compressed air supply to leak or bypass within the air valve
assembly, causing the pump to leak compressed air from the pump air exhaust or not
cycle properly. This is most noticeable at pump dead head or high discharge pressure
conditions. Replace any of these o-rings as required or set up a routine, preventive
maintenance schedule to do so on a regular basis. This practice should include
cleaning the spool and sleeve components with a safety solvent or equivalent,
inspecting for signs of wear or damage, and replacing worn components.

To re-install the sleeve and spool set, lightly lubricate the o-rings on the sleeve with

an o-ring assembly lubricant or lightweight oil (such as 10 wt. air line lubricant). Re-
install one end cap, and retaining ring on the valve body. Using the arbor press or
bench vise that was used in disassembly, carefully press the sleeve back into the valve
body, without shearing the o-rings. Re-install the spool, opposite end cap and
retaining ring on the valve body. After inspecting and cleaning the gasket surfaces on
the valve body and intermediate, reinstall the valve body on the pump using new
gaskets. Tighten the four hex head capscrews evenly and in an alternating cross
pattern, at 150 in./lbs. (16.94 Newton meters).

Advertising