Dc / dc converters, Battery chargers, Series specific information ac / dc power supplies – Schaefer Series C/B 4800 User Manual

Page 3

Advertising
background image

www.schaeferpower.de

Low Power

Low Power

DC / DC Converters

DC

in

DC
out

Battery Chargers

AC

in

DC
out

Battery

Series specific information

AC / DC Power Supplies

AC

in

DC
out

Series C / B 4800

6U

56TE

6U

306 mm

280/320* mm

360/450* mm

309 mm

2.5 kW

3.5 kW

5 kW

5 kW

Input VDC

Cooling

Output VDC

10 –16

2)

VDC

Output

Amps

20 – 32

2)

VDC

Output

Amps

40 – 64

VDC

50 – 80

VDC

Output

Amps

80 –160

VDC

160 – 320

VDC

320 – 380

1)

VDC

320 – 640

2)

VDC

450 – 800

2)

VDC

Output

Amps

Adj.

Range

C 4802
C 4803
C 4804
C 4805
C 4809
C 4806
C 4807
C 4807 J
C 4808
C 4808 J

136
116
92
80
44
36
20
12
10
6

C 4822
C 4823
C 4824
C 4825
C 4829
C 4826
C 4827
C 4827 J
C 4828
C 4828 J

190
160
120
100
60
50
26
14
14
7

C 4832
C 4833
C 4834
C 4835
C 4839
C 4836
C 4837
C 4837 J
C 4838
C 4838 J

C 4842
C 4843
C 4844
C 4845
C 4849
C 4846
C 4847
C 4847 J
C 4848
C 4848 J

240

2)

200

2)

150
130
76
62
36
20
20
10

C 4852
C 4853
C 4854
C 4855
C 4859
C 4856
C 4857
C 4857 J
C 4858
C 4858 J

C 4872
C 4873
C 4874
C 4875
C 4879
C 4876
C 4877
C 4877 J
C 4878
C 4878 J

C 4882 Z
C 4883 Z
C 4884 Z
C 4885 Z
C 4889 Z
C 4886 Z
C 4887 Z
C 4887 ZJ
C 4888 Z
C 4888 ZJ

C 4872 G
C 4873 G
C 4874 G
C 4875 G
C 4879 G
C 4876 G
C 4877 G
C 4877 GJ
C 4878 G
C 4878 GJ

C 4872 K
C 4873 K
C 4874 K
C 4875 K
C 4879 K
C 4876 K
C 4877 K
C 4877 KJ
C 4878 K
C 4878 KJ

260

2)

220

2)

160

2)

140
80
66
40
20
20
10

12
15
24
28
48
60
110
200
220
400

11

– 13

14

– 16

23

– 26

26

– 30

45

– 55

58

– 68

100 – 130
190 – 200
200 – 250
380 – 400

4 kW

5 kW

Input VAC, 1-Phase

Input VAC, 3-Phase

Output Amps

Cooling

Output VDC

115

2)

± 20 %

Output

Amps

230

+ 15 %

– 20 %

3x200

+ 15 %

– 20 %

3x400

+ 15 %

– 20 %

3x480

+ 10 %

– 15 %

Adj. Range

C 4862
C 4863
C 4864
C 4865
C 4869
C 4866
C 4867
C 4867 J
C 4868
C 4868 J

260
220
150
130
72
60
30
16
16
8

C 4882
C 4883
C 4884
C 4885
C 4889
C 4886
C 4887
C 4887 J
C 4888
C 4888 J

C 4862 V
C 4863 V
C 4864 V
C 4865 V
C 4869 V
C 4866 V
C 4867 V
C 4867 VJ
C 4868 V
C 4868 VJ

C 4882 V
C 4883 V
C 4884 V
C 4885 V
C 4889 V
C 4886 V
C 4887 V
C 4887 VJ
C 4888 V
C 4888 VJ

C 4892 V
C 4893 V
C 4894 V
C 4895 V
C 4899 V
C 4896 V
C 4897 V
C 4897 VJ
C 4898 V
C 4898 VJ

260

2)

220

2)

160

2)

140
80
66
40
20
20
10

12
15
24
28
48
60
110
200
220
400

11

– 13

14

– 16

23

– 26

26

– 30

45

– 55

58

– 68

100 – 130
190 – 200
200 – 250
380 – 400

4 kW

5 kW

Input VAC, 1-Phase

Input VAC, 3-Phase

Output Amps

Cooling

Output VDC

115

2)

± 20 %

Output

Amps

230

+ 15 %

20

%

3x200

+ 15 %

– 20 %

3x400

+ 15 %

– 20 %

3x480

+ 10 %

– 15 %

Nom.

Battery

Voltage

Range

B 4861
B 4862
B 4864
B 4866
B 4867
B 4868

220
122
62
50
28
14

B 4881
B 4882
B 4884
B 4886
B 4887
B 4888

B 4861 V
B 4862 V
B 4864 V
B 4866 V
B 4867 V
B 4868 V

B 4881 V
B 4882 V
B 4884 V
B 4886 V
B 4887 V
B 4888 V

B 4891 V
B 4892 V
B 4894 V
B 4896 V
B 4897 V
B 4898 V

220

2)

140
70
60
34
18

12
24
48
60
110
220

12 – 16
24 – 32
48 – 64
60 – 80
110 – 145
220 – 290

C 4803

116

C 4823

160

C 4833

C 4843

200

2)

C 4853

C 4873

C 4883 Z

C 4873 G

C 4873 K

220

2)

15

14 – 16

C 4805

80

C 4825

100

C 4835

C 4845

130

C 4855

C 4875

C 4885 Z

C 4875 G

C 4875 K

140

28

26 – 30

C 4806

36

C 4826

50

C 4836

C 4846

62

C 4856

C 4876

C 4886 Z

C 4876 G

C 4876 K

66

60

58 – 68

C 4807 J

12

C 4827 J

14

C 4837 J

C 4847 J

20

C 4857 J

C 4877 J

C 4887 ZJ

C 4877 GJ

C 4877 KJ

20

200

190 – 200

C 4808 J

6

C 4828 J

7

C 4838 J

C 4848 J

10

C 4858 J

C 4878 J

C 4888 ZJ

C 4878 GJ

C 4878 KJ

10

400

380 – 400

C 4863

220

C 4883

C 4863 V

C 4883 V

C 4893 V

220

2)

15

14 – 16

C 4865

130

C 4885

C 4865 V

C 4885 V

C 4895 V

140

28

26 – 30

C 4866

60

C 4886

C 4866 V

C 4886 V

C 4896 V

66

60

58 – 68

C 4867 J

16

C 4887 J

C 4867 VJ

C 4887 VJ

C 4897 VJ

20

200

190 – 200

C 4868 J

8

C 4888 J

C 4868 VJ

C 4888 VJ

C 4898 VJ

10

400

380 – 400

B 4862

122

B 4882

B 4862 V

B 4882 V

B 4892 V

140

24

24 – 32

B 4866

50

B 4886

B 4866 V

B 4886 V

B 4896 V

60

60

60 – 80

B 4868

14

B 4888

B 4868 V

B 4888 V

B 4898 V

18

220

220 – 290

ZVS topology

ZVS topology

ZVS topology

Eurocassette

(pluggable module for 19“ sub-rack)

Standard

Optional

*) applicable to models >= 150 A input or output current

Wall mount

approx. 19 kg/

*)

22 kg

General

Thermal shutdown with auto restart

Option “rco” for ZVS-modules available (see p.118)

1)

Input supply from PFC also suitable

2)

Suited for wall-mount, alternatives upon request

= increased air flow recommended

Input

No-load input power: 15W typical

Switch-on time: 1 - 2s

Inrush current: 230V AC and 3-phase input:

limited by thermistor

Hold-up time for AC input: 5ms typical

@ nominal input voltage

Output

Response time to ±1 %: 5 - 10ms

Turn-on rise time: Soft-start,

100-300ms typical

OVP without restart for ZVS

Advertising