Frequency designation, Ac / ac inverters, Series iv – Schaefer Series IV User Manual

Page 5

Advertising
background image

www.schaeferpower.de

Inverters

Frequency Designation

Inverters

AC / AC Inverters

with 3-phase output from 1.5kVA to 45kVA

19“ sub-rack / approx. 27 kg

*)

with wall plate / approx.

31 kg

*)

19

"

6U

35

0 mm

500 mm

400 mm

310 mm

19“ Plug-in module / approx. 32 kg

with wall plate /

approx. 36 kg

19"

6U

360 mm

500 mm

400 mm

310

mm

approx. 23 kg / 3.4 kVA

Size A

Size G

Size T1 - T3

Size T4

19"

6U

36

0 mm

500

mm

600 mm

330

mm

Size C

Size D

19"

6U

510

mm

500

mm

600 mm

33

0 m

m

19“ sub-rack / approx. 40 kg

*)

with wall plate / approx.

45 kg

*)

19“ sub-rack / approx. 24 kg

**)

with wall plate / 55/65 kg

*)

Trans -

former

Ø

H

Weight

in kg

Power
in kVA

in mm

T1
T2
T3

190
205
243

75
85
85

8.6

12
15

1.4

2
3

Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required

.

19"

7U

46

0 m

m

500

m

m

800 mm

37

0 m

m

Size E

Size F

19

"

6U

460 m

m

500 mm

800 mm

370 mm

19“ sub-rack / approx. 27 kg

**)

with wall plate / approx.

70/80kg

*)

19“ sub-rack / approx. 28 kg

**)

with wall plate / approx. 104 kg

*)

Attention:
For 3-phase system
3 modules are required.

192

mm

200 mm

176

mm

H

Ø

Standard

Optional

Standard

Optional

Standard

Optional

Standard

Optional

Standard

Optional

Standard

Optional

W

H

D

Size T5 - T8

Trans -

former

H

W

D

Weight

in kg

Power
in kVA

in mm

T5
T6
T7
T8

390
450
450
500

240
280
280
320

233
253
283
280

33
50
66

110

5
8
12
15

Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required

.

Wall mount version

W

H

D

Size T5

Trans -

former

H

W

D

Weight

in kg

Power
in kVA

in mm

T5

335

230

210

33

5

Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required

.

standing version

Transformer refers to 50/60 Hz at the output.
Other frequencies or tropical insulation may
change size and weight.
Attention: For 3-phase system 3 transformers
are required

.

Series IV

Switch mode inverters with output transformers for isolation and voltage transformation

AC output

AC input

3 x Inverter

with input

rectifier

3-phase

3 x Transformer

1 or 3-ph.

.1
.2
.3
.4
.41
.5
.51
.6
.61
.7
.8

40 - 400 Hz adjustable / programmable
45 - 65 Hz adjustable / programmable
any fixed frequency between 40 - 400 Hz
400 Hz
synchronized with 400 Hz mains
50 Hz
synchronized with 50 Hz mains
60 Hz
synchronized with 60 Hz mains
50/60 Hz switchable
800 Hz

Input VAC

1-Phase

Output

kVA

Size

Input VAC

1-Phase

Input VAC

3-Phase

Output

kVA

Size

Cooling

Output

VAC

line-to-line

115

± 20 %

230

+ 15 %

– 20 %

3x200

+ 15 %

– 20 %

3x400

+ 15 %

– 20 %

3x480

+ 10 %

– 15 %

IV 5566
IV 5666
IV 5766
IV 5866

IV 6266
IV 6466

1.5
3
3.6
6

9
15

A
C

D+T1
E + T2

G+T3
G+T5

IV 5586
IV 5686
IV 5786
IV 5886

IV 6286
IV 6486

IV 5566 V
IV 5666 V
IV 5766 V
IV 5866 V

IV 6266 V
IV 6466 V

IV 5686 V
IV 5786 V
IV 5886 V
IV 5886 VF
IV 6286 V
IV 6486 V
IV 6686 V
IV 6886 V

IV 5796 V
IV 5896 V
IV 5896 VF
IV 6296 V
IV 6496 V
IV 6696 V
IV 6896 V

1.8
3.6
5.4
7.5
10
15
24
36
45

A
C

D + T2

E + T3
F + T4

G + T5
G + T6
G + T7
G + T8

3 x 200

IV 5568
IV 5668
IV 5768
IV 5868

IV 6268
IV 6468

1.5
3
3.6
6

9
15

A
C

D+T1
E + T2

G+T3
G+T5

IV 5588
IV 5688
IV 5788
IV 5888

IV 6288
IV 6488

IV 5568 V
IV 5668 V
IV 5768 V
IV 5868 V

IV 6268 V
IV 6468 V

IV 5688 V
IV 5788 V
IV 5888 V
IV 5888 VF
IV 6288 V
IV 6488 V
IV 6688 V
IV 6888 V

IV 5798 V
IV 5898 V
IV 5898 VF
IV 6298 V
IV 6498 V
IV 6698 V
IV 6898 V

1.8
3.6
5.4
7.5
10
15
24
36
45

A
C

D + T2

E + T3
F + T4

G + T5
G + T6
G + T7
G + T8

3 x 400

IV 5569
IV 5669
IV 5769
IV 5869

IV 6269
IV 6469

1.5
3
3.6
6

9
15

A
C

D+T1
E + T2

G+T3
G+T5

IV 5589
IV 5689
IV 5789
IV 5889

IV 6289
IV 6489

IV 5569 V
IV 5669 V
IV 5769 V
IV 5869 V

IV 6269 V
IV 6469 V

IV 5689 V
IV 5789 V
IV 5889 V
IV 5889 VF
IV 6289 V
IV 6489 V
IV 6689 V
IV 6889 V

IV 5799 V
IV 5899 V
IV 5899 VF
IV 6299 V
IV 6499 V
IV 6699 V
IV 6899 V

1.8
3.6
5.4
7.5
10
15
24
36
45

A
C

D + T2

E + T3
F + T4

G + T5
G + T6
G + T7
G + T8

3 x 480

= natural convection

= incl. temperature controlled fans

IV 5666

3

C

IV 5686

IV 5666 V

IV 5686 V

3.6

C

IV 6266

9

G+T3

IV 6286

IV 6266 V

IV 6286 V

IV 6296 V

15

G + T5

IV 6686 V
IV 6886 V

IV 6696 V
IV 6896 V

36
45

G + T7
G T8

IV 5568

1.5

A

IV 5588

IV 5568 V

1.8

A

IV 5888 VF IV 5898 VF

10

F + T4

IV 6468

15

G+T5

IV 6488

IV 6468 V

IV 6488 V

IV 6498 V

24

G + T6

IV 6888 V

IV 6898 V

45

G + T8

IV 5869

6

E + T2

IV 5889

IV 5869 V

IV 5889 V

IV 5899 V

7.5

E + T3

IV 6269

9

G+T3

IV 6289

IV 6269 V

IV 6289 V

IV 6299 V

15

G + T5

IV 5866

6

E + T2

IV 5886

IV 5866 V

IV 5886 V

IV 5896 V

7.5

E + T3

IV 5768

3.6

D+T1

IV 5788

IV 5768 V

IV 5788 V

IV 5798 V

5.4

D + T2

IV 5669

3

C

IV 5689

IV 5669 V

IV 5689 V

3.6

C

IV 6689 V

IV 6699 V

36

G + T7

*)

transformers internal

**)

transformers external

Advertising