0 hydraulic manifold blocks, 1 opener hydraulic blocks, 1 node light definitions – Seed Hawk TOOLBAR 2014 User Manual

Page 31: 2 node diagram, 1 toolbar only, 1 diagnosing node lights

Advertising
background image

SEED HAWK

®

2014 TOOLBAR OPERATOR’S MANUAL

SEED HAWK

®

2014 TOOLBAR OPERATOR’S MANUAL

54

7.3.1 Node Light Definitions

Logic Power: Lights up solid when 12 V is present for Logic Power.

HC Power: Lights up soild when 12 V is present for High Current Power.

Micro 1Hz: Flashes once per second if processor is working correctly.

CAN Rx: Flashes intermittently when CAN communication is present going
TO the node.

CAN Tx: Flashes intermittently when CAN communication is present going
AWAY from the node.

Diagnostic 1 Light: Aircart Node: When solid; indicates that at least one of
the active products is not yet calibrated; e.g missing cal rate, meter cal or valve
cal.

Diagnostic 2 Light: Aircart Node: is not used in any connections.

7.3.1.1 Diagnosing Node Lights

CAN Rx/Tx: OFF - no CAN communication
CAN Rx/Tx: ON - partial CAN communication, possible break in CAN hi/lo
or poor connection.
Micro 1Hz: ON - Node locked up, spike or drop in voltage
Micro 1Hz: OFF - there is no logic power, if there is logic power then node
is bad or logic power is out of range (under 10 V), verify logic power into node
and check source of logic power.

7.3.2 Node Diagram

LOGIC

POWER

HC

POWER

MICRO

1Hz

CAN

Rx

CAN

Tx

DAIG 1

DIAG2

Logic Power
HC Power

Micro 1Hz
CAN Rx
CAN Tx

Diagnostics Light 1
Diagnostics Light 2

NOTE: The Diagnostic 2 light

should be ignored. Although

it blinks, it does not read any

sensors.

55

8.0 Hydraulic Manifold

Blocks

8.1 Opener Hydraulic Blocks

8.1.1 Toolbar Only

T

R-GP

P

RP

A1

B1

GP-2

RP

GP-1

P

T

Pressure

Tank

Inlet Pressure Gauge

PRV Pressure Gauge

Shank Pressure Gauge

Advertising