SEED HAWK

®

2014 AIRCART OPERATOR’S MANUAL

SEED HAWK

®

2014 AIRCART OPERATOR’S MANUAL

58

7.5.3 Clear Field Acres

7.5.4 Rate Controller Meter Setup

This selection allows the operator to enter setup information for the meters.
The default screen is meter 1. Other meters can be selected by pressing the
soft key for the desired meter.

1. Pulses per Rev: This is the num-
ber of pulses generated by the meter
sensor per 1 revolution of the meter
roller. This value is set by default but
can be manually entered. The default
value for a hydraulic drive system is
60.31 pulses per revolution.

1. Move monitor to Aircart and
power up
2. Select Meter Calibration
3. Select desired meter to calibrate

4. Prime roller
5. Calibrate Meter
6. Enter weight of product

Loup III Quick Start Calibration

Choosing this item allows the user to clear the accumulated field acres. 

NOTE: If total acres cannot

be cleared from the settings

menu. Contact your Seed

Hawk Dealer for information

on clearing the total acres

register.

NOTE: Once verified the 

field acres cannot be re-

stored.

1. Using the Selector Knob, high-
light "Clear Field Acres"

2. A dialog box will appear verifying
your selection. Verify by pressing the
Selector Knob or Enter.

2. Low alarm point: This is the minimum meter rpm speed the meter can
turn before the “low meter rpm” or “meter stopped” alarms will display. The
default value is 0.5 rpm.

3. Weight/Rev: This value is determined by the meter calibration procedure or
it can be manually entered.

59

7.5.5 Seeder Stationary Mode

NOTE: This selection must

be disabled before actual

seeding is started.

This selection allows the operator to enter a fake ground speed so the entire
system can be run for a system checkout before entering the field. The entire 
system must be functional to use this selection.

1. Using the Arrow Keys or Selec-
tor Knob
, highlight and select “Seed-
er Stationary Mode.”

2. Dialogue box will appear displaying
status. Using the

Selector Knob

highlight “Disabled” and press to open

4. Increment: This value is the increment value for on the go rate adjust-
ments when seeding. The default value is 5.00 lb/ac.

5. OK/Cancel: Select “OK” to save any changes made. Select “Cancel” to
ignore any changes made.

4. Select “Enable” and enter a fake
ground speed

3.Using the Arrow Keys or Selec-
tor Knob
, highlight and select “En-
able.” Confirm selection by pressing 
the

Selector Knob or Enter.