PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

1. Check to be sure your power source is capable of handling the

voltage requirements of the motor, as indicated on the pump

name plate.

2. These pumps are not designed or intended to be used to handle

sewage or effluent.

3. This pump has been evaluated for use with WATER only.
4. Maximum continuous operating water temperature for standard

model pumps must not exceed 104°F (40°C).

Note: Pumps with the "CSA" mark are tested to CSA Standard

C22.2 No. 108.

REFER TO WARRANTY ON PAGE 2.

PERFORMANCE

Your pump is designed to effectively pump clear all storm and drain

waters. Although it will usually pass small particles suspended in

water, grass, heavy mud, sand or pea gravel can clog the pump

and reduce pump performance. This can usually be cleaned out by

backflushing with a garden hose through the discharge. The normal

performance that can be expected is as follows:

HP

GALLONS PER MINUTE AT

DISCHARGE HEIGHT ABOVE

PUMPING LEVEL

SHUT-OFF

HEAD

5 Ft.

10 Ft.

15 Ft.

1/6

15

11

6

19 Ft.

1/4

30

22

12

20 Ft.

FW0697

0611

Supersedes

0810

DO NOT uSE FOR PuMPING OILS, GASOLINE OR ANY PETROLEuM bY-PRODuCTS.

Notice to Installer: Instructions must remain with installation.

Product information presented

here reflects conditions at time

of publication. Consult factory

regarding discrepancies or

inconsistencies.

1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before

using. Do Not remove the test plug in the cover.

2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials

should be retained for future reference.

1. Make sure there is a properly installed ground fault circuit

interrupter (GFCI) protected circuit available. All pumps are

furnished with provisions for proper grounding to help protect you

against the possibility of electrical shock.

2. Make certain that the ground fault receptacle is within the reach

of the pump’s power supply cord DO NOT USE AN EXTENSION

CORD. Extension cords that are too long or too light do not deliver

sufficient voltage to the pump motor. But, more important, they

could present a safety hazard if the insulation were to become

damaged or the connection ends were to fall into the sump and

become wet.

3. Make sure the pump electrical supply circuit is equipped with fuses

or circuit breakers of proper capacity. A separate branch circuit is

recommended, sized according the National Electrical Code for the

current shown on the pump name plate.

4. TESTING FOR GROUND. As a safety measure, each electrical

outlet should be checked for ground using an Underwriters

Laboratory Listed circuit analyzer which will indicate if the power,

neutral and ground wires are correctly connected to your outlet. If

they are not, call a qualified licensed electrician.

5. Installation and checking of electrical circuits and hardware should

only be performed by a qualified licensed electrician.

6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP

FROM ITS POWER SOURCE BEFORE HANDLING.

7. These pumps are supplied with a 3-prong grounded plug to help

protect you against the possibility of electrical shock. DO NOT

UNDER ANY CIRCUMSTANCES REMOVE THE GROUND

PIN. The 3-prong plug must be inserted in a mating 3-prong

fault interrupter receptacle. If the installation does not have such

a receptacle, it must be changed to the proper type, wired, and

grounded in accordance with the National Electrical Code and all

applicable local codes and ordinances.

8. Risk of electric shock. This pump has not been investigated for use

in swimming pool areas.

9. According to the state of California (Prop 65), this product contains

chemicals known to the state of California to cause cancer and

birth defects or other reproductive harm.

SEE bELOW FOR LIST OF CAuTIONS

SEE bELOW FOR LIST OF WARNINGS

INSTALLATION INSTRUCTIONS

MAIL TO: 95 North Oak Street • Kendallville, IN 46755

(260) 347-1600 • 1 (800) 345-9422 • FAX (260) 347-0909

Quality Products Since 1866!

1/6 HP

115V @ 1.5 Amps

UTHAL

433039

UTFAL

1/4 HP

115V @ 2.5 Amps

2STHAL

473685

2STFAL

115V @1.5 Amps

UTFAL20

115V @2.5 Amps

2STFAL20

MODELS: