Star Water Systems SW Jet Pump User Manual

Star Water Systems Pumps

Advertising
background image

023538 A

SHALLOW WELL JET PUMP QUICK REFERENCE GUIDE

Questions? Call

1-800-742-5044 BEFORE

Returning Product

Copyright © 2011 Star Water Systems. All rights reserved.

CAUTION:

Drain the entire

system if there is

danger of freezing.

A drain plug is

provided at the

bottom of the

pump case for this

purpose.

1/2 and 3/4 HP

Models with

built-in ejector

1 and 1-1/2 HP

Models with

separate,

bolt-on ejector

1 and 1-1/2 HP

Models Only

1 in. Discharge

1-1/4 in.

Suction

1/2 and 3/4 HP

Models Only

To change from 115V to 230V

a. Using a pair of needle nose pliers, pull the

gray wire with the female flag connector

from the “A” terminal spade post. Place it

to the right on the “B” terminal space post.

(

Fig. 2a)

b. Pull the red wire with the female flag

connector from the “L2” terminal. Place it to

the left on the “B” terminal space post.

(

Fig. 2b)

PUMP PRIMING & STARTUP - PRIMING

CAUTION: All pumps must be primed (filling

the cavity with water) before they are first operated.

This may take several gallons of water, as the

suction line will be filled in addition to the pump

cavity.

4. Thread in priming plug and then open optional

ball valve if installed (see page 5) by turning

handle to line up with the pipe.

(Fig. 4)

2. Slowly fill pump cavity until water comes out of

air relief hole on top of the pump. (

Fig. 2)

3. Replace air relief plug and continue adding

water to pump cavity until water reaches the

top of the priming plug.

(Fig. 3)

Water

level in

pump

cavity

1. The motor of this pump is dual voltage and can

run on either 115V or 230V. In general, 230V is

more economical to run, and requires a smaller

wire size. 1/2 and 3/4 HP pumps are pre-set in

the factory to run at 115V. (

Fig. 1)

2. For 230V service, change the following wires

on the terminal board:

PIPE SIZES

Priming Port

Venturi Tube

Ejector

INSTALLATION

1 and 1-1/2 HP Models Only

Attach ejector to face of pump with two (2) bolts

and gasket provided. Venturi tube on the ejector

inserts into the top tapping of the face of the pump

NOTE: 1/2 HP and 3/4 HP models have a

built-in ejector.

Priming plug

with pressure

gauge

Air relief plug

1/2 & 3/4 HP

1. Remove the 1/2 in. priming plug with pressure

gauge and air relief plug. (

1/2 & 3/4 HP Fig. 1a)

(1 & 1-1/2 HP Fig. 1b)

SEE INSTRUCTION MANUAL FOR

COMPLETE DETAILS

ELECTRICAL CONNECTIONS

5. Turn on breaker to start pump

IMPORTANT: If the pump hums instead of

pumping or turns off repeatedly, shut pump off

immediately.

Check voltage. Make sure your incoming voltage

matches the pump wiring voltage. See wiring guide in

the instructions.

1

2

3

4

5

PREVENT PUMP DAMAGE!

Remove plug in freezing weather.

230V

115V

1-1/4 in.

Suction

3/4 in. Discharge

WINTERIZING

Air relief plug

1 & 1-1/2 HP

Advertising