Star Water Systems SJ05SAT20H User Manual

Shallow well jet pump tank system

Advertising
background image

1

CAUTION: Make certain that the power source

matches the pump requirements. Pump has a

dual voltage motor and can run on 115 V or 230

V.

Pump is pre-set at the factory to run on

230 V.

To change pump/tank voltage, remove the

square voltage switch cover at the top of pump/

tank and move the voltage switch as shown.

S

TAR

®

QUICK REFERENCE GUIDE.

SEE INSTRUCTION MANUAL FOR

COMPLETE DETAILS.

b. Connect pump/tank to

well as shown. Connect

1-1/4 in. pipe (not

included) to the pump

suction opening.

4

CAUTION: All pumps must be primed by filling the cavity with water before they are first operated. This will take several gallons

of water, as the suction line must be filled in addition to the cavity of pump/tank. Depending on the length of suction pipe, many gallons

may be needed to fill the entire system.

5

6

SHALLOW

WELL

JET PUMP TANK

SYSTEM

MODEL #SJ05SAT20H

024459 A

Printed in the U.S.A.

Switch cover

Winterizing

CAUTION: Drain the

entire system if there is danger

of freezing.

To drain pump/tank, remove

the drain plug located on the

front of pump/tank and the

vent plug located on the top of

pump/tank.

Wire

from

motor

Ground

Screws

Wire from

power

supply

Open

Terminals

Voltage Switch

115 V

Setting

230 V

Setting

Connect the two wires from

the power supply to the two

open terminals on the pressure

switch. Connect the green

ground wire from the power

supply to the open green

ground screw in the pressure

switch.

Vent plug

Pressure Gauge or

Discharge tee plug

Discharge Tee

Tank Tee

Vent Plug

Opening

Vent plug

Pressure Gauge or

Discharge tee plug

Discharge Tee

Tank Tee

a. Remove pressure gauge or discharge

tee plug (not included) from the top of the

discharge tee (not included). Remove the

vent plug in front of the discharge tee.

b. Slowly fill the discharge tee with water

until water overflows the vent plug

opening. NOTE: Before turning on

pump/tank, loosely replace vent plug and

open several outlets or faucets to allow

water flow during priming.

c. Check to be sure water in the cavity of

pump/tank stays constant. If water level

goes down, it could indicate a leak in

the foot valve, check valve or suction

pipe. If water remains constant, wrap the

pressure gauge or discharge tee plug

and vent plug threads with thread tape

and thread into pump/tank. Tighten with

wrench (not included).

2

3

Connect discharge tee and pressure gauge or

discharge plug (all not included) to tank tee.

1 in. Discharge Pipe

To Home

Tank Tee

Discharge

Tee

c. Air pressure in the tank must be 2 PSI

lower than the “cut-in” of the pressure

switch. Pump/tank has a 20/40 PSI

pressure switch, so tank pressure must

be set at 18 PSI. Check pressure with

a tire gauge (not included) and add or

subtract air as needed.

a. Remove plastic

plug from suction

opening.

Vent Plug

Drain

Plug

Advertising