LAWN PUMP QUICK
REFERENCE GUIDE

SEE INSTRUCTION MANUAL FOR
COMPLETE DETAILS

1

Questions, problems, missing parts?
Before returning to your retailer, call our
customer service department at
1-800-742-5044, 7:30 a.m. - 5 p.m., EST,
Monday - Friday.

NOTE: This pump is equipped with a 2 in. inlet for
maximum water spray.

• 2 in. inlet (suction) opening can be reduced with

some loss in performance. If reducing below
1-1/2 in., call factory.

• 1-1/2 in. outlet (discharge) pipe can be reduced with

some loss in performance. If reducing below 1-1/4 in.,
call factory.

NOTE: Pump may show water
stains as a result of factory
water testing.

TYPICAL INSTALLATION

CHECK YOUR BREAKER BOX

115V

230V

WARNING: Always disconnect

pump from electricity before performing
any work on the motor.

The motor of this pump is dual voltage and can run
on either 115V or 230V. This pump is pre-set in the
factory to run at 230V.

For 115V service, remove the motor cover and
change the following wires on the terminal board:

a. Using a pair of needle nose pliers, pull the gray

wire with the female flag connector from the “B”
terminal spade post. Place it to the left on the
“A” terminal space post.

HERE’S HOW TO CHANGE THIS
PUMP FROM 230V TO 115V

1. b. Pull the red wire with the female flag connector

from the “B” terminal. Place it to the right on the
L2 terminal space post.

A

B

L2

L1

A

B

L2

L1

Water Level

25 ft.

max

Vertical

Lift

Outlet Pipe

Inlet

Pipe

Discharge to

Sprinkler System

Inlet pipe to water

Pipe

Support

60 ft. max.

Motor Cover

Foot

Valve

WHAT CONTROLS WILL YOU USE WITH
THIS PUMP?

Pump Start Relay

Pressure Switch with
Tank

Indexing Valve

NOTE: This pump can be used with a variety of
controls. See control manufacturer’s instructions
for details.

This pump is wired for 230V

Need
115V?

see sectioN 4

230V

115V

For installation videos, scan with
your smart phone.

1. Disconnect the

outlet union and
separate the pipe.

2. Remove priming plug with

pressure gauge and the
air relief plug on top of
pump.

3. Slowly fill pump cavity until

water comes out of the air
relief hole.

4. Replace air relief plug and

continue adding water to
pump cavity until water
comes out the open
outlet pipe at the open
union.

6. Reconnect union on outlet

pipe. Open the ball valve
(turn handle to line up
with pipe), and then
turn on breaker to start
pump.

CAUTION: All pumps must be primed (filling

the cavity with water) before they are first operated.
This may take several gallons of water, as the inlet
line will be filled in addition to the pump cavity. The
longer the inlet line, the more water is required to
prime.

HOW TO PRIME YOUR PUMP

Outlet

Priming plug with
pressure gauge

Air relief
plug

Inlet

5. Wait 10 minutes to see if

water level drops below
the pipe tee. If level
drops, check foot valve.
If level stays constant,
re-install the priming plug.

Pipe
Tee

5