D. the regeneration cycle, E. starting the unit, Figure d – Star Water Systems Metered Valve User Manual

Page 2

Advertising
background image

indicates how many gallons of soft water remain before a
regeneration will take place.

NOTE: FOR WATER WITH RUST STAINS:

If iron is present in the water supply as evidenced by red
stains on clothes, fixtures, toilets, etc., add 12 grains per
gallon to the actual water hardness.

To keep the softener resin bed iron free, mix two ounces of
Super Iron Out® or similar iron cleaner with every 80 lbs.
of salt added to the brine compartment, or use salt that
contains an iron control agent.

D. THE REGENERATION CYCLE

The regeneration cycle will take between 84 and 104
minutes, and will go through 8 different cycles. It will be
normal to hear water flowing during this time. Water will be
available for use during the regeneration process, but it will
not be softened. Figure C shows approximate cycle time for
each process.

E. STARTING THE UNIT

1) To ensure unit is installed and working properly,

briefly rotate the indexing knob clockwise through
the following cycles: “Backwash”, “Brine Rinse”, and
“Brine Refill” (about 60 seconds for each cycle.) While
in each cycle, listen for water flow, and check system
for any leaks.

2) Return indexing knob to “Service” position. Water flow

should stop. The softener is now ready to provide
softened water on demand.

3) The control valve will actually meter the water flow,

and regenerate only after a specific amount of water
has been used. Not only will you enjoy softened water,
but you will enjoy the economical savings as well.

DIAL READING

CYCLE TIME

1. In Service
2. Regeneration
3. Rinse
4. Backwash
5. Brine + Rinse
6. Rapid Rinse
7. Settle Rinse
8. Brine Refill

5

Min.

Rinse

10

Min.

Backwash

50

Min. Brine + Rinse

10

Min. Rapid Rinse

5

Min. Settling Rinse

4 - 24

Min. Brine Refill

FIGURE D

FLOW METER

Advertising