Star Water Systems S07AF10 Filter User Manual

Page 5

Advertising
background image

5

9. STARTING THE UNIT

Place the control valve in the SERVICE POSITION and

follow these steps:
(a) Place the by-pass valve (valves) to SERVICE position

and allow water to flow into the mineral tank. On a

3-valve system (Figure 2) open the inlet and outlet

valves and close the by-pass valve.

(b) When the water stops flowing, open a treated water tap

until all air is released from the lines, then close the

tap.

(c) Manually index knob to the BACK WASH POSITION.

(Clockwise rotation.)

(d) Plug in the electrical cord. Set the days of backwash

desired. Set the time of day as also noted in Section 7.

On all units except carbon filters, allow the unit to

backwash 15 minutes or until the water becomes clear

at drain. This will wash out the fine material from the

mineral. Check water at drain to be certain large

quantities of mineral are not being lost. If so, return

valve to IN SERVICE position and allow mineral to soak

longer before being backwashed.

NOTE: WHEN INSTALLING A CARBON FILTER, IT IS

BEST TO ALLOW AT LEAST 3 HOURS OR

PREFERABLY OVERNIGHT FOR CARBON TO SOAK

BEFORE ATTEMPTING TO BACKWASH. TO SPEED

WETTING, OPEN THE FAUCET OF THE TREATED

SUPPLY AND ALLOW TO RUN 5 MINUTES OR

LONGER OR UNTIL WATER IS CLEAR. IF

CONSIDERABLE CARBON IS STILL BEING LOST

WHEN BACKWASHING, LEAVE IT SOAK FOR A DAY

OR TWO LONGER.

(e) Position to RAPID RINSE. The automatic valve will

automatically return to IN SERVICE after approximately

17 minutes.

10. BACKWASH

Units will now Backwash on a frequency as established in

Step 7 “Setting the Time Control.”

11. EXTRA BACKWASH

Valve can be manually regenerated by turning the control

knob to the Backwash position. The unit will automatically

continue through the regeneration cycle and return to the

SERVICE position when regeneration is complete.

12. TO SKIP BACKWASH

For vacations or extended periods of absence, the timer

cord plug can be pulled out of receptacle. Upon return, plug

in timer, reset the time of day (Section 7-A) and backwashing

will resume as normal.

13. FINAL CHECKOUT

(a) Be certain by-pass valve is closed and inlet and outlet

valves are fully open.

(b) Check electrical supply to be certain cord is connected

to an uninterrupted 115 volt outlet.

(c) Be certain warranty card is filled out and mailed in.

14. ADDITIONAL INFORMATION

(a) Carbon filter mineral must be replaced periodically to

ensure filter effectiveness. Maximum carbon life is three

years.

(b) Calcite filter mineral dissolves slowly. Therefore, it will be

necessary to add calcite to the unit from time to time.

Advertising