Tele Vue RMF-2003 User Manual

Tele Vue Hardware

Advertising
background image

INSTRUCTIONS RMK-2002/RMF-2003

Parts List:
Digital Indicator Kit
RMK-2002/RMF-2003 for
2" focusers on TV-76,
TV-85, TV-102, NP101
- Digital Indicator
- Indicator Dovetail
- Dovetail Channel
- Indicator Stop Bracket
- (2) Stop Bracket Screws
- Nylon Runners (washers)
- (2) Phillips Head Screws
- (2) Allen Keys

Installation
Step 1)

Step 1)

Step 1)

Step 1)

Step 1) Remove the two but-
ton head screws from the top
of the focuser body with the
provided Allen key.
Step 2)

Step 2)

Step 2)

Step 2)

Step 2) Remove the two
screw hole plugs from the
top of the focuser's draw
tube using a small jeweller's
screwdriver.
Step 3)

Step 3)

Step 3)

Step 3)

Step 3) Place the Dovetail
Channel over the focuser body
as shown and secure it using
the two phillips head screws.
Step 4)

Step 4)

Step 4)

Step 4)

Step 4) Slide the Indicator
Dovetail onto the back of
the Digital Indicator and lock
in place using the small Allen
key.
Step 5)

Step 5)

Step 5)

Step 5)

Step 5) Slide the Indicator
into the Dovetail Channel.
Step 6)

Step 6)

Step 6)

Step 6)

Step 6) Slip the Nylon Wash-
ers on to the Stop Bracket
Screws.
Step 7)

Step 7)

Step 7)

Step 7)

Step 7) Place the Indicator
Stop Bracket over the draw
tube with the stop towards
the Indicator.
Step 8)

Step 8)

Step 8)

Step 8)

Step 8) Lock the Indicator
Stop Bracket Screws.

Proceed with the adjustment
instructions.

Adjustment and Use
The Digital Indicator has
0.5" of travel. It is ideal to
set the shaft within the
middle of its travel range.

To do so: achieve a

rough focus with your tele-
scope. Slide the indicator
against the stop until the
shaft has moved approxi-
mately half way through its
travel. Use the small Allen
key and tighten the two set
screws on the side of the
Dovetail Channel that con-
tact the indicator Dovetail.
If the indicator needs more
or less adjustment room to
reach the stop, first deter-
mine if repositioning the Stop
Bracket will help. For more
adjustment, remove the digi-
tal indicator from the chan-
nel, loosen the set screws
(see step 4) and slide the
Indicator Dovetail in the nec-
essary direction. Retighten
the set screws.

Turn the micrometer on

and zero it if necessary

Start critically focusing

the image. Take note of the
micrometer reading so you
may return to that position if
further adjustment does not
improve focus.

Details regarding the

use of the indicator can be
found on the instructions in-
cluded with the unit.

The optional RSC-2320

cable plus TVFocus software
(download available at
www.TeleVue.com) permits
remote viewing of the
indicator's reading.

32 Elkay Drive, Chester, New York 10918 845.469.4551 www.televue.com

Digital Indicator

Indicator
Stop
Bracket

Dovetail
Channel

Indicator
Dovetail

Steps 1 & 2

Step 3

Step 4

Step 5

Step 6

Step 7 & 8

Micrometer position

adjustment