American Standard Swan 6011 User Manual

Page 2

Advertising
background image

3

INSTALL HANDLE

ADJUST HOT LIMIT STOP

By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).

1

51

31

19

75

31

0

1

5

1

3

1

1

9

7

5

3

1

1

5

1

3

1

1

9

7

5

3

1

4

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a
flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4) and
NUMBERS (5) on HOT LIMIT STOP (1) for indication.

1

5

1

5

4

4

3

3

2

2

Push ADAPTER (3) onto VALVE STEM (4).

Install SCREW (2) through ADAPTER (3) into
VALVE STEM (4).

Find correct position of HANDLE (1) and push
HANDLE (1) onto ADAPTER (3).

Install SET SCREW (5) with (2.5mm) HEX
WRENCH (6) provided.

Check proper operation of HANDLE (1).

Turn on water supply and test installed fitting.
Operate valve and diverter spout.

A

2

INSTALL TRIM

6

7

3

1

4

5

2

9

8

CAUTION: Protect finish on SHOWER ARM,
SHOWER HEAD and TUB SPOUT when installing.

SHOWER ARM
FLANGE

SPOUT FLANGE

3

1

5

6

4

M 9 6 8 4 6 2 S - O

2

When finished tiling the wall, remove PLASTER GUARD (A)
and turn off water supply.

Push CAP (1) over VALVE CARTRIDGE (2).

Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4).

Remove PIPE CAP (5) from shower pipe. Use sealent on both
ends of SHOWER ARM (6) and thread long end into shower
elbow. Thread SHOWER HEAD (7) to SHOWER ARM (6).

Remove PIPE CAP (9). Use tubing cutter to cut tub filler
pipe a minium of 1-1/2" from finished wall. Install SLIP-ON
SPOUT (8) with flange flush against finished wall and tighten
with a 4mm (5/32") hex wrench.

1-1/2"

MIN.

4mm (5/32") HEX WRENCH

Advertising