Page 4

STEP 1. After the installation site has been

selected for the fan, remove any insulation from the

area and select a ceiling joist to be the center line

of the fan.

Use the shutter carton to make a template for the

opening your shutter requires. (See above) FROM

THE ATTIC SIDE OF THE INSTALLATION SITE place

“CSS” SERIES SHUTTER INSTALLATION

Models CSS-24, CSS-30 & CSS-36, install on joists with 16" or 24" centers.

Model CSS-42 installs on 24” centers only.

CAUTION: DO NOT CUT THE SHUTTER OPENING

THE SAME SIZE AS THE FAN OPENING.

Use the shutter inside dimensions as shown in the

shutter specification chart below.

OPENING SIZES

- Installs centered on a joist with 16

"

or 24

"

centers.

Cut two openings, one on each side of center joist per shutter model:

Model

Fan Size

Outside Dimension

Opening Size

CSS-24

24" 24" x 32" 10

1

/

4

" x 30

1

/

4

"

CSS-30

30" 32" x 35" 14

1

/

4

" x 34

1

/

4

"

CSS-36

36" 32" x 43" 14

1

/

4

" x 41

1

/

4

"

*

CSS-42 42"

38" x 49"

17

1

/

4

" x 46

3

/

4

"

*

For 24" o.c. joists only

the template on the ceiling and against the joist that

will be the center of the fan. With a pencil trace

around the template. Repeat this procedure on the

exact opposite side of the joist. Drill a

1

/

4

" hole at each

corner of the pencil lines. YOU SHOULD HAVE EIGHT

(8) HOLES. From directly below the attic, check to be

sure that the location is correct.

STEP 2. Return to the attic, and using a utility knife

or sheetrock saw carefully cut the shutter opening

following the pattern on both sides of the joist. (See

fig. 5).

DO NOT REMOVE THE SHEETROCK

FROM THE CENTER JOIST.

STEP 3. Frame the opening using lumber EQUAL

TO THE SIZE OF THE EXISTING JOISTS. (See fig. 6).

STEP 4. If the opening is less than the distance

between the joists, fasten supports between the new

framing along the edge of the opening. (See fig. 8.).

STEP 5. Remove the two (2) screws that secure the

fan frame to the plenum. Pass the fan and plenum into

the attic through the framed opening in the ceiling.*

Set them aside at this time.

Platform

New framing

Fig. 5

Fig. 6

Fig. 7

“CSS” SHUTTERS

*

If the fan does not fit through

the framed opening, use your

attic access opening. The current

building code requires this access

opening to be at least 22" x 30".