Universal Air Tools UT176RL User Manual

Foreseen use of the tool, Putting into service air supply, Operator instructions important

Advertising
background image

Manufacturer/Supplier

Product Type

RPM

Cycles Per Min

Tel No

Fax No

(01494) 883300

(01494) 883237

Model No/Nos

Serial No

Product Nett Weight

lbs
Kg

Recommended Use Of

Balancer Or Support

Recommended Hose Bore

Size - Minimum

Recommended Max.

Hose Length

Ins

M/M

Ft

M

Foreseen Use of the Tool

The air engraving pen is used to write/etch on hard steel, glass, stone,
ceramic and plastic, etc. The writing/etching is achieved by a
reciprocating/vibrating sleeve item (14) and is particularly useful to
identify jigs and fixtures and to personalise tools and other equipment in
the workshop.
Do not modify or use the tool for any other purpose or for its use as an
engraving pen without first agreeing any such modification with the
manufacturer or an authorised agent.

Putting Into Service
Air Supply

Use a clean lubricated air supply that will give a measured air pressure
at the tool of 90 p.s.i./6.3 bar when the tool is running with the trigger
fully depressed. Use recommended hose size and length. It is
recommended that the tool is connected to the air supply as shown in
figure 1. Do not connect the tool to the air line system without
incorporating an easy to reach and operate air shut off valve. The air
supply should be lubricated. It is strongly recommended that an air filter,
regulator, lubricator (FRL) is used as shown in Figure 1 as this will supply
clean, lubricated air at the correct pressure to the tool. Details of such
equipment can be obtained from your supplier. If such equipment is not
used then the tool should be lubricated by shutting off the air supply to
the tool, depressurising the line by pressing the trigger on the tool.

No

Page No 1

Engraving Pen

UT176RL

0.48
0.22

3/8

10

30

10

Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules

Operator Instructions

Important

Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.

Universal Air Tool Company Limited

Unit 8

Lane End Industrial Park

High Wycombe

Bucks

HP14 3BY

Vibration Level

Test Method

Tested in accordance with ISO

standards 8662/1

Less than 2.5

Noise Level

Test Method

Tested in accordance with Pneurop

test code PN8NTC1 and ISO Standard 3744

Work Stations

The tool should only be used as a handheld, hand operated tool. It is
always recommended that the tool is used when standing on a solid
floor. It can be
used in other
positions but
before any such
use,

the

operator must
be in a secure
position having
a firm grip and
footing and be
aware of a
reaction force
on the hand as
result of the tool
doing work.

N/A

13,000

Metres / Sec²

Personal Safety Equipment

Use - Safety Glasses

Yes

Use - Safety Gloves
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors

Air Pressure

Recommended Working

6.3

bar

90

PSI

Recommended Minimum

n/a

bar

n/a

PSI

Maximum

7.0

bar

100

PSI

Sound Pressure Level 78.0 dB(A)
Sound Power Level 90.0 dB(A)

Advertising